KAPSCH TRAFFICCOM CANADA INC. 802295 User Manual

Page of 282
JANUS
®
 Multi-Protocol Reader Ver. 2: Maintenance Instructions  
 
Confidential 
UM
 
360450-210: A7 
Page 228 of 282 
© Kapsch TrafficCom Canada Inc. 2013 
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom  Canada Inc. and are issued in strict 
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or 
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc. 
 
 
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 
 
10/31/2013 7:56 
Kapsch TrafficCom 
 
7.  Select the Switchover on Serial Link Down and/or Switchover on Ethernet LC Link Down check box, as 
required.  
8.  Press 
Enter or select a different tab to accept the selections. 
Note: When setting the LC Retry Timeout, consider the baud rate used to communicate with the LC and the 
processing speed of the LC to avoid false failure reports.  
9.  If 
Switchover on Serial Link Down is enabled, from the Serial tab on the Configuration page, enter a time, 
in milliseconds, in the 
LC Retry Timeout field. If an LC does not respond within this time, the Reader will 
consider serial communications to the LC to be down and will trigger a switchover if the SPM redundancy 
mode switch is in 
AUTO
10.  If 
Switchover on Ethernet LC Link Down is enabled, enter a time, in milliseconds, in the LC Ethernet TCP-
Socket Timeout text box. If an LC does not respond within this time, the Reader will consider Ethernet 
communications to the LC to be down and could trigger a switchover if the SPM redundancy mode switch is in 
AUTO
To configure the Reader to switch over when the Ethernet IR link is down 
Prerequisites:  Multiple Reader communication method set to Ethernet in the 
Lane Assignment tab 
of the 
Configuration page. 
1.  Select the 