KAPSCH TRAFFICCOM CANADA INC. 802295 User Manual
_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential
UM 360450-210 Revision: A7
Page
52 of 282
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX
10/31/2013 7:56
Kapsch TrafficCom
Table 3-4 Reports by Channel
Reports by Channel tab on Statistics page
Field
Description
Last Update
The date and time that the statistics in the browser window were
updated. Navigate away from and then return to the
Statistics
page, or refresh/reload your browser screen to update the
statistics.
Channel
The RF Channel that the statistics in that row represent.
Total
The total number of transactions
AvgHS
The average number of handshakes over the total transactions
with the primary or secondary side active
Pgm
The number of transactions where data is sent to the OBU.
PF
The number of times programing to the OBU has failed.
PU
The number of times the Reader cannot determine if a
programming attempt was successful.
PU/PF%
The percent of PU and PFs per total programming attempts
Decom
The number of decommissioned OBUs
NonIAG
The number of OBUs not belonging to the Group ID for which
the Reader is provisioned.
RdOnly
The number of transactions where data is read from the OBU,
with no programming occurring; this does not include program
fails.
CRA
The number of transactions reported as Cross Reader.
Overall PU/PF
rate
The average across all channels
Latency
The average latency time to report transactions