KAPSCH TRAFFICCOM CANADA INC. 802295 User Manual

Page of 282
JANUS
®
 Multi-Protocol Reader Ver. 2: Operating Instructions 
 
Confidential 
UM 360450-210 Revision: A7  
Page 
52 of 282 
© Kapsch TrafficCom Canada Inc. 2013 
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom  Canada Inc. and are issued in strict 
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or 
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc. 
 
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 
 
10/31/2013 7:56 
 
Kapsch TrafficCom 
Table 3-4 Reports by Channel 
Reports by Channel tab on Statistics page 
Field 
Description 
Last Update 
The date and time that the statistics in the browser window were 
updated. Navigate away from and then return to the 
Statistics 
page, or refresh/reload your browser screen to update the 
statistics. 
Channel 
The RF Channel that the statistics in that row represent. 
Total  
The total number of transactions  
AvgHS 
The average number of handshakes over the total transactions 
with the primary or secondary side active 
Pgm 
The number of transactions where data is sent to the OBU.  
PF 
The number of times programing to the OBU has failed. 
PU 
The number of times the Reader cannot determine if a 
programming attempt was successful. 
PU/PF% 
The percent of PU and PFs per total programming attempts 
Decom 
The number of decommissioned OBUs 
NonIAG 
The number of OBUs not belonging to the Group ID for which 
the Reader is provisioned. 
RdOnly 
The number of transactions where data is read from the OBU, 
with no programming occurring; this does not include program 
fails. 
CRA 
The number of transactions reported as Cross Reader. 
Overall PU/PF 
rate 
The average across all channels 
Latency 
The average latency time to report transactions