Casi Rusco 1000-1010 User Manual
Model 1000/1010 Dual Tech (Prox/MagStripe) Reader
37
Technical Specifications
Operating Temperature Range:
5 to 66
o
C (41 to 150
o
F)
With Optional Cold Weather Kit:
-35 to 66
o
C (-31 to 150
o
F)
Humidity Range:
0 to 95%, noncondensing
Physical Dimensions:
4.75" (H) x 6.00" (W) x 1.63" (D)
121 mm (H) x 152 mm (W) x 42 mm (D)
Index of Protection:
IP34
Maximum Cabling Distance:
The reader will work well with
unshielded cable in most environments. No company, including
CASI-RUSCO, can guarantee that data will be reliably transmitted for
long distances on unshielded cable in every installation. The following
distances are for reference only. Refer to the appropriate installation
wiring diagrams for specific information.
12V operation: * 500 feet on standard 20 AWG telephone wire
48V operation: One mile on standard 20 AWG telephone wire
*
12V operation: * 500 feet on standard 20 AWG telephone wire
48V operation: One mile on standard 20 AWG telephone wire
*
12V operation implies that a 12V power supply is located up to 500
feet from the reader. The use of an auxiliary power supply close to
the reader may allow operation at greater distances.
Power Supply:
Nominal 12 to 48V DC, 200 mA at 12V and 70 mA at 48V
Color:
Light grey
Door Strike Relay:
Maximum contact rating of 0.75 amperes*.
Maximum contact voltage of 28V AC or DC.
Maximum Reader Range:
6 inches with a ProxLite or Proximity
Perfect badge. The read range depends on many variables, such as the
interference from other electronics equipment (like computer monitors or
two-way radios).
*
A relay has been designed into the reader for maximum flexibility.
The life of the relay will decrease as the current switched by the
contacts is increased. Use low current door strikes for high traffic
doors to maximize the relay life. Use an external relay for high