8.10 OPTIONAL ENHANCED RAM+ SECOND STATION MIC
AND/OR VH-310 HANDSET INSTALLATION
The GX3000S is capable of using up to 2 Enhanced RAM+ mics or VH-310
Handset to remotely control the Radio, DSC, and Distress functions. In addition
the GX3000S can operate as a full function intercom system.
1. Connect the Routing Cable to the one of the Remote Mic eight pin connec-
tor on the rear panel, then tighten the Cable Nut (See Figure 2).
2. Referring to Figure 3, make a 1.2” (30 mm) hole in the wall, then insert  the
Routing Cable into this hole. Connect the Gasket and Mount Base to the
Routing Cable Connector using the Nut.
3. Drill the four Screw holes (approx. 2 mm) on the wall, then install the Mounting
Base to the wall using four screws.
4. Put the Rubber Cap on to the Nut. The installation is now complete.
5. Wires for a external speaker are provided on the Routing Cable. Connect
any 8 Ohm external speaker. When connected the RAM+ (or VH-310  Hand-
set) controls the volume level of this speaker.
Figure 2
Figure 3
Wall
Gasket
Mounting Bracket
Routing Cable
Cap
Nut
Black and White wires are for
connection of a MLS-300 or
MLS-310 External Speaker
FCC ID: K6630143X3D/IC ID: 511B-30143X3D