Yaesu Musen Co. Ltd. 30143X3D User Manual

Page of 100
Page 63
GX3000S
12.8  SCAN RESUME TIME
This selection is used to select the time the GX3000S waits after a transmis-
sion ends before starting scanning.
1. Press and hold down the [CALL(MENU)] key until
Radio Setup
” menu appears.
2. Press the [ENT] key, then select “
SCAN Resume
” in
the “
Radio Setup
” menu with the CHANNEL selec-
tor knob.
3. Press the [ENT] key.
4. Turn the CHANNEL selector knob to select the de-
sired resume time. The resume time can be set to
1sec
,” “
2sec
,” “
3sec
,” or “
Off
.” In the “
Off
” selec-
tion, the scanner will resume after the other station
stops transmitting (carrier drops).
5. Press the [ENT] key to  store the selected setting.
6. To exit this menu and return to radio operation mode press the [16/9] key.
12.9  KEY BEEP (ON/OFF)
This selection allows the beep tone when a key is pressed to be turned off.
1. Press and hold down the [CALL(MENU)] key until
Radio Setup
” menu appears.
2. Press the [ENT] key, then select “
Key Beep
” in the
Radio Setup
” menu with the CHANNEL selector
knob.
3. Press the [ENT] key.
4. Turn the CHANNEL selector knob to select “
On
” or
Off
.”
5. Press the [ENT] key to set the key beep condition.
6. To exit this menu and return to radio operation mode
press the [16/9] key.
NOTE
Emergency alarm and beeps for DSC operation cannot be turned OFF.
FCC ID: K6630143X3D/IC ID: 511B-30143X3D
Vertex Standard Co., Ltd.