 5.
Close all other applications running on the computer (especially programs that 
use the serial COM port, e.g. HyperTerminal). The load program may not execute 
successfully if other programs are running.
In the HSD folder, double-click on the ADT_LOAD.exe to launch the load program.
The ADT_LOAD application opens in a DOS window and displays the “Load 
Target” menu.
 6.
Select Menu item 7, HPA application plus boot, and then press Enter.
 7.
The system prompts you for a filename. (i.e. “Filename which contains the 
firmware image?”) 
Note:
Use care to ensure that the correct file name is entered for the HSD 
transceiver’s power type.
 8.
Enter
 
A1703006-V9A6.SX
 for a 28 V dc unit 
 9.
Enter C0300106-V4A2.SX for a 115 V ac unit
 10.
Press Enter
The program prompts you to select a COM port.
 11.
Select the COM port on your computer connected to the HSD. 
 12.
Type the appropriate COM port (1 or 2—typically 1), and then press Enter
 13.
To start the load, press Enter.
A percentage (%) progress indicator appears on the screen. A confirmation 
message briefly appears on the screen indicating that the file has been 
HSD/HST LOADER   Vx.x -- Mon Mar 24 12:12:17 2003
which target ?
   0 = control processor
   1 = channel card #1
   2 = channel card #2
   3 = HPA application
   4 = data i/o card
   5 = HPA application with manual setup
   6 = HPA application plus boot with manual setup
   7 = HPA application plus boot
   8 = channel card #1 boot code
   9 = channel card #2 boot code
   11 = channel card #1 pic code
   12 = channel card #2 pic code
   13 = HCM application
   14 = HST ORT
   15 = HSD ORT
   16 = HSD-X ORT
   ?