Enter 1 thru 203 to toggle report on/off
X  turn off all reports    <CTRL> N  show next page    S   save to EEPROM
ESC  return to PREVIOUS MENU
181 OFF data i/o call reports           194 OFF PA reset cycles
182 OFF recovery after BGAN inert       195 OFF sys table protection algorithm
183 OFF debug CC#1 rx parser            199 OFF classic AERO call status
184 OFF debug CC#2 rx parser            202 OFF CFDS pages sent to CMC
185 OFF dio / cc call matchup           203 OFF generic HD710 faults
187 OFF antenna steering OLS labels     
188 OFF over-power protection algorithm  1 OFF OFF messages to card #1
189 OFF expanded IRS input               2 OFF OFF hex output to card #1
190 OFF miscellaneous debugging          3 OFF OFF responses from card #1
191 OFF WSCI telephony                   4 OFF OFF hex input from card #1
192 OFF CMU status words                 5 OFF OFF card #1 misc info
193 OFF output to antenna controller     6 OFF sb antenna arinc input
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion® HSD-440 Mark 2 Terminal
23-15-30
4-56
3 JUN 10
Figure 4-13   HSD-440 Mark 2 Terminal MPU Reports
(7) Activating Maintenance Reports 
To automatically generate report 23 (standard output) in Level 1 menu access, press 
the EQUAL SIGN. The report data output is repeated on the computer display at 
one-second intervals. 
Level 2 maintenance access provides more flexibility in the use of the reports 
function. This access level permits the activation or deactivation of any one of the 
reports (toggle on and off).
(a) Reports General Guidelines
 •
To open the report menu, press EQUAL SIGN.
 •
To activate a report, type the number of the report needed, and then press 
ENTER. This toggles on the report number entered. To toggle the report off, 
type the report number again, and then press ENTER. 
 •
To disable all reports (toggles all reports off), press X.
 •
To display the next group of reports, press CTRL+N.
 •
To save all selected reports to EEPROM, press S. The selected reports will 
then be output automatically when the maintenance port is accessed. If the 
items selected are not saved, they are de-activated when the system is reset 
or power is cycled to the terminal.
 •
To start the scrolling report display, press ESC (in Level 2 access only). To 
return to the menu selection screen, press ESC again. 
(b) Report Descriptions
Not all the reports are used in the testing or troubleshooting of the system. This 
section describes only the more commonly used reports.