* These bits are cleared when the chime light inhibit discrete signal is asserted.
15
Message Alert with 
Chime
 •
Refer to MCDU messages for timely information
  •
Terminal should clear this bit once positive pilot response has 
been detected
16
Message Alert without 
Chime
 •
This bit is never set, it is reserved for future use.
17
Not Logged-On
 •
Terminal is not logged onto a ground station
18
Master/Slave
 •
This bit is never set, slave operation is not supported.
 •
19
CMU 2 Inactive
 •
CMU 2 transmission of valid Label 270 is detected inactive
 •
Label 270 SSM coded to fail on CMU #2
 •
Label 270 bit 20 is not set
20
Cockpit Fault
 •
Not used
21
Cockpit Voice Fault
 •
Not used
22
Voice Call 1
 •
Terminal has detected a low priority (4) flight deck incoming 
voice call on channel 1
23
Voice Call 2
 •
Terminal has detected a low priority (4) flight deck incoming 
voice call on channel 2
24
Voice Alert 1
 •
Terminal has detected a high priority (1, 2, or 3) flight deck 
incoming voice call on channel 1
25
Voice Alert 2
 •
Terminal has detected a high priority (1, 2, or 3) flight deck 
incoming voice call on channel 2
26
Cockpit Voice 
Communication 1
 •
A cockpit voice communication is connected on channel 1
27
Cockpit Voice 
Communication 2
 •
A cockpit voice communication is connected on channel 2
28
 •
Never set
29
Data
 •
No active CMU is available at the SDU, or the active CMU 
does not respond with a Loop Word in response to a Test 
Word
 •
This bit being set can be caused by the following: 
 •
Bus inactivity on all CMU inputs
 •
Bus activity, but no declared active CMU
 •
Bit may be used to set a cockpit advisory message (for 
example, >SATCOM DATA) indicating to the flight crew a loss 
of data link capability due to a failure in the CMU interface.
 Table F-3  Status Word 1 Bits (Continued)
Bit(s)
Description
If Set