16
6.2
SPI AC Characteristics
The following specification identifies the required hardware timing to successfully
implement a SPI interface with the Airborne Device Server module.
implement a SPI interface with the Airborne Device Server module.
Table 12 - SPI AC Timings
Symbol
Parameter
Min
Typ
Max
Units
f
MAX
Maximum Clock Frequency
8.00
MHz
t
CS
SPI Select Low to Clock Rising Edge
100
ns
t
CH
Clock High
62.5
ns
t
CL
Clock Low
62.5
ns
t
DA
Clock High to Data Out
60
ns
t
DS
Clock Low to Data In Valid Set-up time
14
ns
t
DH
Clock Low to Data Valid Hold time
2
ns
t
CSH
Clock Falling Edge to SPI Select High
100
ns
t
DELAY
SPI Select High to SPI Select Low
40
µs
Figure 1 - SPI Read/Write Timing