 Receiver Programming
S E C T I O N  3
3.2 Enroll Wireless Devices Using
Zones (WLS904, WLS905, WLS906,
WLS907, WLS908 and WLS915)
Enroll wireless devices which use zones (universal
transmitters, motion detectors, smoke detectors, and
panic pendants):
1. At a system keypad, enter [✱][8][Installer’s code]
to go the installer’s programming section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the
zone the device is to occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be
assigned to the same zone. PC5108 zone expander
modules occupy zones in 2 groups of 4 (e.g. zones
9-12 and zones 13-16). None of the zones assigned
to a PC5108 module may be used for wireless
devices. For more information on zone assignment,
consult your system Installation Manual.
4. Enter the device’s ESN. The entry 
must be six
digits. If an older device with a 5-digit ESN is being
enrolled, add the digit [0] to the beginning of the
ESN. (E.g. ESN=21234, enter 021234)
5. The device is now enrolled on the system. Record
the serial number and the assigned zone number
in the programming worksheets in the back of this
manual.
6. Continue with steps 3 - 5 until you have enrolled
all wireless devices.
7. To exit press [#].
NOTE: The devices will not work properly until you
complete zone and partition programming (see
section 4).
Enroll & Program Devices
This section describes how to enroll and program:
• wireless devices using zones (WLS904, WLS905,
WLS906, WLS907, WLS908, and WLS915)
• wireless keys (WLS909)
• handheld keypads (WLS910).
For more information on these devices, read the
instruction sheet included with each device.
3.1 A Note about Electronic Serial
Numbers
An electronic serial number (ESN) is printed on the
back of each wireless device. ESNs are used to enroll
the wireless devices with the LCD5501Z32-900
keypad.
In order to reduce the occurrence of wireless
devices with the same serial number, 6-digit serial
numbers are now printed on the back of each
wireless device.
NOTE: 6-digit serial numbers are only supported on
the following control panels: PC5010 v2.x and higher,
PC5015 v2.2, PC5008, PC1555 and PC580.
The 6-digit serial numbers include hexadecimal digits.
For instructions on programming hexadecimal numbers,
see your system Installation Manual, section 4: How to
Program.
When connecting the LCD5501Z32-900 to a PC5010 or
PC5015 v1.x panel, enter 5-digit serial numbers only.
When connecting the LCD5501Z32-900  to a PC5010
v2.x, PC5015 v2.x, PC5008, PC1555 or PC580 panel
follow the instructions below.
Old Wireless Device ESNs
You can use older devices on all versions of the
LCD5501Z32-900 keypad, even though they only have
a 5-digit ESN. When using older wireless devices:
E
E
E
E
Enter [0] + 5-digit ESN
nter [0] + 5-digit ESN
nter [0] + 5-digit ESN
nter [0] + 5-digit ESN
nter [0] + 5-digit ESN