O T H E R  P R O G R A M M I N G
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by
default. To disable supervision for any zone, enter
the following at any system keypad:
1. Enter [✱][8][Installer Code] to enter Installer
Programming.
2. Enter [804] to enter the PC5132 Module
Programming.
3. Enter sections [82], [83], [84] and [85]. Disable
or enable supervision for each wireless zone by
turning each relevant option on or off.
4. To exit press [#].
4.4 RF Jam Detect Zone
For RF jamming detection to work, you must select an
unused zone to be used as the RF Jam Detect zone.
When the receiver detects an attempt to jam the RF
signal, the RF Jam Detect zone will be violated and
the system will generate a tamper signal. When the
jamming signal is gone, the RF Jam Detect zone
closes and the system sends a tamper restore signal.
To enable RF jamming detection:
1. Enter [✱][8] [Installer’s Code].
2. Enter programming section [804].
3. Select an unused zone to be the RF Jam Detect
zone. Enter the 2-digit number ([01] to [32]) of
the RF Jam Detect zone on the keypad, then
program the serial number as [200000].
3. Enter section [93]. Enter the 2-digit number of the
RF Jam Detect zone ([01] to [32]) in the
programming section.
4. Disable supervision for the RF Jam detect zone
by turning the relevant option off in section [82],
[83], [84] or [85]. (See section 4.3 for more
information.)
5. RF jamming detection is now enabled. To exit
Installer programming, press [#].
4.5  Receiver Software Default
Returning the receiver programming to factory default
settings is a quick way to remove all the enrolled
devices from the system and reset all the
programming in section [804].
NOTE: Performing this procedure will not change any
programming sections except [804]. Resetting the
control panel to factory default settings will not re-
turn the PC5132 to factory default settings.
To restore the PC5132 programming to the factory
default settings, perform the following:
1. Enter [✱][8] [Installer’s Code].
2. Enter programming section [996].
3. Enter the Installer’s Code, followed by [996] again.
Press [#]. The software for the receiver section
will be restored to its factory default settings.
4. Press [#] to exit Installer Programming. After a
software default, you must exit and then re-enter
Installer Programming before attempting to
program the receiver section.
For instructions on restoring the default programming
of the control panel or any other connected module,