4 Power up Sequence
7
PGM - The PGM output is 
dedicated for Skyroute 
CL3050 trouble indica-
tions.  If a control panel is 
not monitoring the Sky-
route CL3050, an LED or a 
buzzer can be connected 
between this terminal and 
the RED terminal for trouble 
indication.  The PGM termi-
nal switches low from an 
open-collector state.  Con-
nect to the control panel 
using a Single EOL configu-
ration as shown
Note: The PGM output can 
sink 50 mA (maximum).
4 Power up Sequence
On first-time power up, the Skyroute CL3050 will generate a random test trans-
mission time and random day of the week to send it. The installer can then 
change this information if required. 
During power up, the Skyroute CL3050 will look for a keypad on the Keybus, if 
one is found, it will go into programming mode.  If no keypad is found, it will 
look for a PC5108 zone expander module.  If a zone expander is found, it will 
automatically configure itself for mode 3.  If no Keybus modules are present, the 
Skyroute CL3050 will power up in mode 1.  During the first 15  seconds of power 
up, any zone scanning will be shunted.  During this time the installer can momen-
tarily press the enroll button on the Skyroute CL3050 to toggle between mode 1 
and mode 2.  Upon power up the green LED will be flashing on and off.  This will 
indicate to the installer that he/she can change the mode to 1 or 2. The red LED 
will indicate mode 1 and the yellow LED will indicate mode 2. If neither red or yel-
low LED is lit, then the Skyroute CL3050 has detected a PC5108 module, the 
mode cannot be changed by pressing the enroll button if a PC5108 module is 
connected to the Skyroute CL3050.
If a keypad is detected on Keybus, the green LED will stop flashing, and the red 
LED will begin flashing to indicate that programming mode is active.
RED    BLK   YEL  GRN  COM  PGM
LED        560
Ω
LED Output with
current limiting
resistor
Optional relay 
driver output 
+        Coil      -
Relay
To External
Supply
NC              Com
Skyroute CL3050