1.1 Unpacking
The RF5501-433 package includes the following parts:
The RF5501-433 package includes the following parts:
The RF5501-433 package includes the following parts:
The RF5501-433 package includes the following parts:
The RF5501-433 package includes the following parts:
• One RF5501-433 keypad
• Two 5.6K Ohm resistor
• Four mounting screws
• One keypad inner door label
• One set of Fire, Auxiliary and Panic key labels
• One LCD5501Z User Sheet
• One RF5501-433 Installation Manual
1.2 Mounting
You should mount the keypad where it is accessible to designated points of entry and
exit. Once you have selected a dry and secure location, perform the following steps to
mount the keypad:
1. Remove the keypad backplate by loosening the screw located at the base of the unit.
2. Secure the keypad backplate to the wall in the desired location. Use the screws provided.
3. Before attaching the keypad to its backplate, complete the keypad wiring as described
in the next section.
Ensure the mounting location is:
Dry
Central to the proposed placement of all wireless devices
Far from sources of interference, including electrical noise (computers, televisions,
electric motors in appliances and heating & air conditioning units), large metal objects
such as heating ducts and plumbing which may shield the antenna.
1.3 Wiring
1. Before beginning to wire the unit, ensure that all power (AC transformer and battery) is
disconnected from the control panel.
2. Connect the four Keybus wires from the control panel (red, black, yellow, green) to the
keypad terminals (R B Y G). Consult the diagram below:
RF5501-433
R
B
Y
G
P
1
P
2
/
Z
Red Blk Yel Grn P1 P2/Z
3. You can connect a device, such as a door contact, to the “Z” terminal of the RF5501-433.
This eliminates the need to run wires back to the control panel for the device. To connect the
zone, run one wire from the device to the Z terminal and the other wire from the device to the
B (black) terminal. For powered devices, run the red wire to the R (positive) terminal and
the black wire to the B (negative) terminal. When using end of line supervision, connect the
zone according to one of the configurations outlined in your system’s 
Installation Manual.
Installation
S E C T I O N  1
NOTE:  P
1
 
 and P
2
 
 are open collector programmable
outputs. Refer to the control panel manual for proper
hook-up diagram.  P
2
 
 is  also the zone input terminal
when programmed (see section [90]).  DEOL is
supported by this keypad.