For further information on the terms “Control string” and “User code” used in the following sections,
please refer to the “I/O” and “Options->Codes” sections of the “PROGRAMMING VIA PC” chapter.
Bistable outputs (GS3125 only)
Open collector outputs set as bistable can be activated in 2 ways:
1. By sending an SMS consisting of the User code between two # characters, the Control string  (Control String can not
have initial blank spaces) and the characters “=ON#”, as follows:
#User code#String=ON#   (example: #9876#HOUSELIGHT=ON#)
2. Through  caller identification: in this case the output is activated at “cost-free” as the Communicator, after identifying the
caller, rejects the call and activates the output.
A bistable OC output can ONLY be deactivated by sending an SMS message consisting of the User code
between two # characters, the Control string and the characters “=OFF#,as follows:
#User code#String=OFF#   (example: #9876#HOUSELIGHT=OFF#)
The default User code is ‘0001’; if you wish to change it, please refer to the section “Remote programming by SMS
message->Changing the User code”.
Monostable Outputs
OC outputs set as Monostable may be activated in 2 ways, through Caller Identification and via SMS (GS3125 only).
SMS (GS3125 only)
Send an SMS consisting of the User code between the # characters, the Control string  (Control String can not have
initial blank spaces) and the characters “=ON#”,“=ON#TonU#” or “=OFF#”,as follows:
#User code#String=ON#
#User code#String=ON#TonU#
#User code#String=OFF#
The “=ON#tonU#” option is  parameter allows  to set the ON Time from 1 to 86400 seconds, with 1 second steps. The ON
Time
 can be set by means of the Communicator’s console software. “Ton” is the required value and “U” is the unit in hours
(H), minutes (M) and seconds (S), as shown in the following example:
Remove the “TonU” parameter, leaving the “##” characters, to activate the output by SMS as programmed.
(example: #9876#HOUSELIGHT=ON##)
Caller Identification
Through  caller identification: in this case the output is activated at “cost-free” as the Communicator, after identifying the
caller, rejects the call and activates the output.
Monostable OC outputs deactivate (switch OFF) automatically when the programmed ON Time expires.
Only the T3 output of the GS3105 can be activated through Caller Identification.
The  ON time may be set to a period of time between 1 and 86400 seconds, in steps of 1 second.
The default User code is ‘0001’; if you wish to change it, please refer to the section “Remote programming by SMS
message->Changing the User code”.
SMS
Output operating mode
#9876#HOUSELIGHT=ON#
Bistable Activation
#9876#HOUSELIGHT=ON#3600S#
Active for 3600 seconds
#9876#HOUSELIGHT=ON#50M#
Active for 50 minutes
#9876#HOUSELIGHT=ON#3600#
Active as per software programming,
the set ON time does not apply