Digital Security Controls Ltd. 16WS90029 User Manual
Chapter 8.0 Viewing Troubles on the Integrated Keypad
8.0 Viewing Troubles on the Integrated Keypad
When the system detects a trouble condition, the Trouble
indicator turns on and the system
beeps once every 10 seconds. Tap the [*] key to silence the beeps.
Note: For UL Listed installations, your access code is required to view system troubles.
To view troubles on the integrated keypad, do the following steps:
Note: For UL Listed installations, your access code is required to view system troubles.
To view troubles on the integrated keypad, do the following steps:
1. When the keypad illuminates, tap [*][2].
2. Enter your access code, if required. The Trouble indicator flashes if an access code is
required.
The system indicates top-level trouble codes by illuminating the corresponding numbers on the
keypad, and the Trouble indicator flashes once with a pause, then repeats.
keypad, and the Trouble indicator flashes once with a pause, then repeats.
3. Tap one of the numbers to see the next level code. At the second level, the Trouble indic-
ator flashes twice with a pause, then repeats.
4. Repeat step 3 to go to the next level. The system beeps if there is no third-level trouble
condition. At this level, the Trouble indicator flashes three times with a pause, then
repeats.
If there is more than one zone in trouble, each zone number will flash in sequence until you exit the
trouble menu or when the time expires. At this level, the Trouble indicator flashes three times with
a pause, then repeats.
trouble menu or when the time expires. At this level, the Trouble indicator flashes three times with
a pause, then repeats.
5. Tap [#] to return to the previous level trouble code or to exit the trouble menu.
Top Level
Device Type
Device Type
Second Level
Trouble Type
Trouble Type
Third Level
Device ID
Device ID
01
System Trouble
01
AC
Not applicable
02
Battery Trouble
03
Tamper
04
RF Jam
02
Zone
01
AC
1-128
02
Battery Trouble
03
Tamper
04
Fault (supervision)
05
Not Networked
06
Fire/CO Trouble
03
Siren
01
AC
1 to 16
02
Battery Trouble
03
Tamper
04
Fault ( supervision)
05
Not Networked
04
Keypad
01
AC
1 to 4
02
Battery Trouble
03
Tamper
04
Fault ( supervision)
05
Not Networked
- 19 -