Digital Security Controls Ltd. 17LE4000 User Manual

Page of 29
15
6.6 Reporting Codes
6.6 Reporting Codes
LE4000 Reporting Codes
CID
SIA
Programmable
Comments
Zone 1 Activation
E130 991
FA 991
YES
Delayed 24 Hour Fire *
Zone 1 Restoral
R130 991
FH 991
YES
Delayed 24 Hour Fire Restore *
Zone 2 Activation
E300 992
PA 992
YES
Panic Alarm *
Zone 2 Restoral
R300 992
PH 992
YES
Panic Alarm Restore*
PSTN Line Down
E351 000
LT 000
FIXED
Telco 1 Fault
PSTN Line Restoral
R351 000
LR 000
FIXED
Telco 1 Fault Restore
Input Loss
E337 000
YP 000
FIXED
Power Supply Trouble
Input Restoral
R337 000
YQ 000
FIXED
Power Supply Trouble Restore
Low Battery Alert
E338 000
YT 000
FIXED
Transmitter Battery Trouble
Low Battery Restoral
R338 000
YR 000
FIXED
Transmitter Battery Restore
Periodic Test
E603 XXX
RP XXX
FIXED
Test Transmission <Receiver Path>
Periodic Test with Trouble
E608 XXX
RY XXX
FIXED
Test Transmission <Receiver Path>
Radio Activation
R552 000
RS 000
FIXED
Remote Programming Successful
Internal Buffer Full
E624 000
JL 000
FIXED
FTC Restoral
R354 000
YK 000
FIXED
Communications Restored
Firmware Update Successful
R901 000
LS 000
FIXED
Firmware Update Fail
E902 000
LU 000
FIXED
Firmware Update Begin
E901 000
LB 000
FIXED
System Tamper
E145 000
ES 000
FIXED
Expansion Module Tamper
System Tamper Restore
R145 000
EJ 000
FIXED
Expansion Module Tamper Restore
* C24 Communications default value
6.7 Swinger Shutdown
To prevent "runaway" signals to the central station, the LE4000 is equipped with Swinger Shutdown which limits certain trouble
events to a maximum of four reports every 24 hours. At midnight, the condition restores and the counter is reset. Swinger Shutdown
applies to the following trouble conditions:
l
System Tamper/Restore
l
Low Battery Trouble/Restore
l
TLM Trouble/Restore
l
Input Power Trouble/Restore
l
FTC Restore
l
Zone 1 and 2 input alarm / restore