2.1.1 Technical Specifications
2.1.1 Technical Specifications
The input voltage to the 3G4010/LE4010 can be drawn from the UL/ULC Listed control panel or provided by
an external UL/ULC Listed power supply rated for the application (external power-limited source).
Note: The power supply must be Class 2, Power Limited. For residential applications a suitable power adaptor
is model DSC ADP1310(W)-NAU or DSC ADP1320-NAU (for USA) and model DSC ADP1310(W)-NA (for
Canada).
Table 4-1 Ratings
Power Supply Ratings
Input Voltage:
9-14Vdc (use separately listed control panel or power supply) or 13.8Vdc (use DSC ADP1310
(W)-NAx or ADP1320-NAx power adapter)
Current Consumption
Average Current (standby with PSTN
connected):
40mA*
Average Current (standby without
PSTN connected):
55mA*
Transmission Current (no battery):
225mA*
* Plus any current drawn from the 3G4010/LE4010 AUX+ terminal
Working Voltage Range
With Battery:
11-14Vdc
Without Battery:
9 -14Vdc
Battery Type:
sealed, rechargeable type, rated 12V/1.2Ah
(for 24hr standby time)
Battery charging voltage:
13.75Vdc
Battery charge current limit:
360mA
NOTE: Battery must be replaced every 3-5 years.
NOTE: When using the battery, use DSC ADP 1310-NAU(W) or ADP 1320-NAU power adapter
Operating frequency - 2G
(GSM/GPRS/EDGE):
850/1900MHz
Operating frequency - 3G
(UMTS/HSPA):
850/1900MHz
For LE4010 operating frequencies, see
table below.
Antenna gain:
2.0dBi
Environmental Specifications
Operating temperature:
0°C-49°C (32°F-120°F)
Humidity:
93%RH Maximum (non-condensing)
Mechanical Specifications