Digital Security Controls Ltd. 17TL280LER User Manual

Page of 60
Communication Standard - October 1997. This format will send the account code along with its data
transmission. The transmission will look similar to the following at the receiver.
NOTE: This section shall sync with PowerSeries Neo panels version 1.00 or higher.
Example:
Nri0 ET001 where: = New Event; ri0 = Partition/Area identifier; ET = Panel Absent Trouble; 001 =
Zone 001.
Communications Reporting Codes
Table 9: Communications Reporting Codes
Event
SIA
Identifier
SIA
Reporting
Code
CID
Qualifier
CID
Event
Code
CID
Reporting
Code
CID
User/Zone
[023] Panel Absent Trouble
ET
0001
1
3
55
001
[024] Panel Absent Trouble
Restore
ER
0001
3
3
55
001
[026] Ethernet 1 Test
Transmission
RP
0001
1
6
A3
951
[027] Ethernet 2 Test
Transmission
RP
0002
1
6
A3
952
[028] Cellular 1 Test
Transmission
RP
0003
1
6
A3
955
[029] Cellular 2 Test
Transmission
RP
0004
1
6
A3
956
[030] FTC Restore
YK
0001
3
3
54
001
[023] Panel Absent Trouble
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the
panel have been lost for more than 60 seconds.
[024] Panel Absent Trouble Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the
control panel have resumed.
[025] Radio Activation Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur in North American cellular com-
municators when the unit has been programmed by Connect 24.
System Test Options
Test Transmissions to Primary Receiver, with Backup to Secondary Receiver:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
l
If the test transmission fails to the primary receiver it will back up to the secondary receiver.
l
If the test transmission fails to the secondary receiver an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet section [026] to (FF); [027] to (FF). Set cellular section [028] to (FF); [029] to (FF).
l
The module will send periodic test transmissions to each receiver independently, with no backups.
l
If the test transmission fails to any of the programmed receivers, an FTC trouble will be generated.
Alternate Test Transmission:
Alternate test transmission can be enabled or disabled in section [005] toggle option [7].
Alternate Test Transmission with Backup Receivers:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
Interval 1:
l
If the test transmission fails to the primary receiver, it will back up to the secondary receiver.
l
If the test transmission fails to the secondary receiver, an FTC trouble will be generated.
23