ADC Telecommunications Inc. PRSM070A User Manual
Managing Alarms
Page 272
FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc
ADCP-77-073
• Issue 2 • 11/2009
RmtSERFOptRxBERFault
Minor
Too many errors on
the receiving fiber
the receiving fiber
Check fiber for kink
or sharp bend. Check
for too much gain.
Make sure the fiber
is clean.
or sharp bend. Check
for too much gain.
Make sure the fiber
is clean.
RmtSERFOptRxNoLightFault
Major
No light detected
from the receiving
fiber
from the receiving
fiber
Check for broken or
disconnected fiber.
Check for out of
service Host
disconnected fiber.
Check for out of
service Host
RmtSERFOptUnderDriveFault
Minor
The power of the
signal received on
the fiber is too weak
signal received on
the fiber is too weak
Check fiber for too
much gain, dirty
connectors. Check
SFP type being used
(too weak for range)
much gain, dirty
connectors. Check
SFP type being used
(too weak for range)
RmtSERFSynthAlarmFault
Major
Onboard
synthesizer fault
synthesizer fault
Check clock signal
coming from Host.
Host is not
generating a proper
signal. Possibly Host
clock source is bad
or Host has bad
FPGA
coming from Host.
Host is not
generating a proper
signal. Possibly Host
clock source is bad
or Host has bad
FPGA
RmtSystemVswrFault
Major
LPA VSWR Fault
Perform cable
sweeps on external
antenna cable
system. Put a load on
the Remote by
disconnecting the
external antenna
cable to determine if
the source of the
VSWR condition is
internal or external.
If it's internal,
replace the RF
Module. If it's
external,
troubleshoot and
determine source of
high VSWR reading.
sweeps on external
antenna cable
system. Put a load on
the Remote by
disconnecting the
external antenna
cable to determine if
the source of the
VSWR condition is
internal or external.
If it's internal,
replace the RF
Module. If it's
external,
troubleshoot and
determine source of
high VSWR reading.
RmtUnderTempFault
Minor
Temperature is
below lower
acceptable limit (-40
degrees Farenheit)
below lower
acceptable limit (-40
degrees Farenheit)
Check ambient
conditions
conditions
Table 11-1. EMS Alarm Descriptions and Corrective Actions (Cont.)
Alarm Name
Alarm
Severity
Level
Severity
Level
Description
Action