Table 5. System Specifications (Continued)
PARAMETER
SPECIFICATION
REMARKS
RF Forward Path
System
 Bandwidth
25
 MHz
Frequency
 range
Cellular:
 869 to 894 MHz
Output
 power
+13
 +/– 1 dB
composite
Gain
 variation
+/–
 3 dB
<
 1.5 dB variation
Over
 frequency, temperature,
and
 unit-
Per
 1.25 MHz CDMA channel
IP
3
>
 +35 dBm
CDMA
 ACPR1
<
 –45 dBc
Spurious
 Output
<
 –35 dBm
DHU
 input signal level
–20
 dBm maximum
Provides
 a +13 dBm RF output
signal
 at the DRU
RF Reverse Path
System
 bandwidth
25
 MHz
Frequency
 Range
US
 Cellular: 824 to 849 MHz
Gain
10
 +/– 1 dB
Gain
 Variation
+/–
 3 dB
<
 1.5 dB variation
Over
 frequency, temperature,
and
 unit-unit
Per
 1.25 MHz CDMA channel
Automatic
 Gain
Limiting
Prevents
 A/D saturation with
large
 inputs. Disabled for
composite
 RF input < –40 dBm
Noise
 Figure
<
 12 dB
10
 + 10 log n (n = # of users)
DHU
 output signal level
–30
 dBm maximum
With
 a –40 dBm composite
maximum
 input signal at the
DRU
Physical/Electrical - DHU
Weight
17.5
 lbs (7.9 kg)
RF
 connection
Type
 N
female
Alarm
 connection
Screw
 terminals (14–26 AWG)
NO,
 NC, and COM
Optical
 connection
Duplex
 LC adapter
DC
 power connection
RJ-45
female
Power
 source
120–240
 VAC, 50–60 Hz
Power
 consumption
24
 W
typical
Current
 rating
85–250
 VAC, 2 Amp input
(Continued)