TransCore 05531 User Manual

Page of 278
Encompass 4/4800 Multiprotocol Reader System Guide
7-16
Reader response:
Done
 
or
 
Error
490 Disable Third Alternate Group Select (Factory Default)
Command #490 is a default set in the factory to disable the third alternate group select 
function. 
Reader response:
Done
491 Enable Third Alternate Group Select
Command #491 enables the third alternate group select function that allows the reader 
to distinguish tags meeting specific criteria pre-programmed into the tags. 
Caution
When third alternate group select is enabled, tags not programmed to meet the spec-
ified criteria will not be read.
Reader response:
Done
 
or
 
Error
492 Disable Fourth Alternate Group Select (Factory Default)
Command #492 is a default set in the factory to disable the fourth alternate group 
select function. 
Reader response:
Done
493 Enable Fourth Alternate Group Select
Command #493 enables the fourth alternate group select function that allows the 
reader to distinguish tags meeting specific criteria pre-programmed into the tags. 
Caution
When fourth alternate group select is enabled, tags not programmed to meet the 
specified criteria will not be read.
Reader response:
Done or Error
494 Disable Fifth Alternate Group Select (Factory Default)
Command #494 is a default set in the factory to disable the fifth alternate group select 
function. 
Reader response:
Done