TransCore 05531 User Manual
Encompass 4/4800 Multiprotcol Reader System Guide
4-8
Connecting Communications for Bench Testing
TransCore offers reader models that communicate through RS
–
232, RS
–
422, and
Wiegand interface protocols. This section describes the procedures and materials
required for connecting the communications to perform pre-installation bench testing
of the Encompass 4/4800 Multiprotocol Reader.
required for connecting the communications to perform pre-installation bench testing
of the Encompass 4/4800 Multiprotocol Reader.
Required Materials
You need the following materials to connect the communications cable to the PC:
•
PC or laptop
•
Any terminal emulation program such as Procomm Plus™ or Hyper Terminal™
running on a PC
running on a PC
•
Communications cable to connect to the COM1 port on your PC
Encompass 4/4800 Multiprotocol Reader communications and customer interface sig-
nals are supplied from the Encompass 4/4800 Multiprotocol Reader to the host
through a multiwire cable, which is a 13-pair pigtail. The connector for this cable is
located on the back of the Encompass 4/4800 Multiprotocol Reader. Refer to the fol-
lowing sections to connect the appropriate communications wires from the cable to
the PC.
nals are supplied from the Encompass 4/4800 Multiprotocol Reader to the host
through a multiwire cable, which is a 13-pair pigtail. The connector for this cable is
located on the back of the Encompass 4/4800 Multiprotocol Reader. Refer to the fol-
lowing sections to connect the appropriate communications wires from the cable to
the PC.
These sections contain instructions for connecting RS
–
232 and RS
–
422 communica-
tions between the Encompass 4/4800 Multiprotocol Reader and the PC for bench test-
ing purposes. Each section contains wiring instructions and pin assignments followed
by step-by-step connection procedures.
ing purposes. Each section contains wiring instructions and pin assignments followed
by step-by-step connection procedures.
The Encompass 4/4800 Multiprotocol Reader can remain powered up while connect-
ing reader-to-host PC communications.
ing reader-to-host PC communications.
Connecting for Bench Testing with RS
–
232 Interface
RS
–
232 interface signals are supplied by three or five wires from the Encompass 4/
4800 Multiprotocol communications cable. The pin assignments for the signal to the
host male DB9 and DB25 connectors are shown in boldface in
host male DB9 and DB25 connectors are shown in boldface in
.