Commands
7-13
450   Disable Wiegand Mode (Factory Default)
Command #450 is a default set in the factory to disable Wiegand mode. 
Reader response:
Done
451   Enable Wiegand Mode
Command #451 enables Wiegand mode, which allows the reader to transmit data in a 
format that emulates the output of a magnetic card reader.
In Wiegand mode, the reader transmits Wiegand-formatted tag data through the Wie-
gand interface and ASCII data (the reader accepts reader commands and responds) 
through the serial port interface. The reader outputs data from Wiegand-programmed 
tags via the Wiegand interface (the red/blue pair for data1/data0; yellow/black pair for 
logic ground). Tags that are not Wiegand-formatted are not transmitted through the 
Wiegand interface or the serial port when in Wiegand mode, although the tag lock 
relay is activated on any tag acquired.
Reader response:
Done
 
or
 
Error
452   Disable Tag Translation Mode (Factory Default)
Command 452 disables tag translation mode. Incoming full-frame tags will be directly 
converted to ASCII. They will not be translated from Association of American 
Railroads (AAR) and American Trucking Associations (ATA) format to ASCII. 
Reader response:
Done
453   Enable Tag Translation Mode
Command 453 enables the translation of tags in AAR and ATA formats. Specific data 
fields, such as owner ID and car number, will be extracted from these tags, translated 
according to AAR or ATA standards, and converted to ASCII. Tags that are not 
programmed in AAR or ATA format will be directly converted to ASCII. The reader 
will not attempt to translate data from half-frame or dual-frame tags. 
Reader response:
Done
454 Disable Multi-tag Sort (Factory Default)
Command #454 is a default set in the factory to disable the multi-tag sort function. 
Reader response:
Done