3.  Connect the reader multiplexer (READER port) to the 
antenna multiplexer (READER port) using the flexible RF 
coaxial cable. Tighten all RF cable connections to 10 in/lb. 
Connect the antenna multiplexer to Universal Toll Antennas 
as required for site configuration. 
Before Getting Started
 
TransCore’s Encompass Multiprotocol Reader with EPCglobal 
Class 1-Generation 2 Reader Module is designed to read from all 
standard tag protocols in North America, including the EPC 
protocol tags. This document contains basic reader module setup 
and user instructions. 
4.  Connect and secure the DB9 data cable between the ANT 
MUX/CHK TAG connector on the Encompass reader and the 
reader multiplexer. 
Encompass Multiprotocol Reader Setup 
5.  Connect EPCglobal Reader Module to reader multiplexer 
(ANT1 port) using the RF cable provided. Tighten all RF cable 
connections to 10 in/lb (Figure 1). 
Please refer to the Encompass multiprotocol reader system guide 
for detailed setup and user instructions on that product. 
You’ll need the following equipment to complete installation: 
6.  Switch on power to the Encompass reader and EPCglobal 
Reader Module. 
Torque-limiting wrench (in/lb range) 
Standard set of tools (wrenches, screwdrivers, and pliers) 
Figure 1 shows the properly assembled EPCglobal Reader 
Module and reader and antenna multiplexer configuration on the 
Encompass reader. 
Installing the Reader Module and Reader 
Multiplexer 
Operating the EPCglobal Reader Module 
and Multiplexer Options 
The EPCglobal Class 1-Generation 2 Reader Module is designed 
to operate in conjunction with TransCore’s antenna multiplexer 
assembly used as a reader multiplexer. 
Once the Encompass reader, EPCglobal Reader Module, and 
reader multiplexer and antenna multiplexer assemblies are 
installed and powered up, follow the system guide instructions to 
connect the reader to a host computer. Once you have 
established communication between the reader and host 
computer, configure the digital I/O as four outputs using the Set 
Digital I/O Port Configuration command. 
To install the EPCglobal Reader Module on the Encompass 
Reader 
1.  Install the reader multiplexer assembly on the Encompass 
reader housing using the four standoffs provided (Figure 1). 
Secure the module to the reader housing using the Phillips 
screws provided with the kit. 
2.  Install the EPCglobal Reader Module on the Encompass 
reader housing and using the four standoffs provided (Figure 
1
). Secure the module to the reader housing using the Phillips 
screws provided with the kit. 
Set Digital I/O Port Configuration 
This command configures the digital I/O ports. Table 2 and  
Table 3 list the command and response data.  
3.  Connect the EPCglobal Reader Module terminal to the 
Encompass multiprotocol reader TDM/COM1 port as shown 
in Figure 2
Table 2. Set Digital I/O Port Configuration Command (0010H) 
Set Digital I/O Port Configuration Command 
Data 
Data Payload
Set Digital I/O Port Configuration Command 
0010H 
Port Configuration 
0FH 
4.  Connect the reader multiplexer assembly (ANT0 port) to the 
Encompass reader (RF MONO port) with the RF cable and 
tighten both SMA connectors to 10 in/lb (Figure 1). 
 
10 
 7