Reader Functionality 
20 
AYC-Ex5 and AYC-T65 Installation and Programming Manual 
5.
 
Reader Functionality 
The AYC-Ex5 series and the AYC-T65 can function both as a reader 
and as a controller. If the unit is connected to standard access 
controller, it functions as a reader, indicated by one beep immediately 
after power-on reset. 
The following explains how the AYC-Ex5 and AYC-T65 function as a 
reader. 
5.1
 
Transmit Mode 
When the unit is in Transmit mode, it is ready to receive data from a 
presented proximity card or an entered PIN code. 
When the reader is in Transmit mode, 
the Transmit LED is red and the 
Program LED is off. 
 
When a proximity card or PIN entry is being transmitted, the Transmit 
LED flashes green. 
PIN data can be sent via one of eight different Keypad Transmission 
Formats (see Section 
Proximity cards presented to the reader are always sent in either 
Wiegand 26-Bit, Clock & Data or, Wiegand Card + PIN format (see 
Section 
5.2
 
Programming the AYC-Ex5 and AYC-T65 
Programming the AYC-Ex5 and AYC-T65 is done solely via the unit's 
keypad driven Programming Menu System. To reach the 
Programming Menu System, the unit must first be placed into 
Programming mode. During the unit’s manufacturing process, certain 
codes and settings are pre-programmed. These settings are called the 
default factory settings. 
Table 2 shows the names of all the AYC-Ex5 and AYC-T65 reader 
menus. 
Mode/Transmit 
Door/Program 
Red