Psion Inc 9160RA2050 User Manual

Page of 8
 
 
TECHNICAL ACQUAINT # 124a 
 
Page 1 of 8    
 
 
SUBJECT:     
9160 Wireless Gateway Installation Guide  
 
 
ORIGINATOR: Gabrielle 
Neff 
 
DATE:    
 
DISTRIBUTION:  TA and FCN Distribution List 
 
IMPORTANT:  The 9160 must be installed by qualified Psion Teklogix personnel. 
Choosing The Right Location 
Typically, Psion Teklogix conducts a site survey in the plant and then recommends the preferred locations 
for the 9160s. These locations provide good radio coverage, minimize the distance to the host computer or 
network controller, and meet the environmental requirements. 
Environment 
The 9160 Wireless Gateway should be located in a well-ventilated area and should be protected from 
extreme temperature fluctuations (i.e. direct heater output, shipping doors or direct sunlight). If a 
protective cover is required, it must have enough ventilation to maintain the 9160’s surface at or near 
room temperature.  
Refer to “Chapter 25: Specifications” in the 9160 Wireless Gateway User Manual for a more detailed 
description of environmental requirements. Keep in mind that the long term stability of this equipment 
will be enhanced if the environmental conditions are less severe than those listed in this manual. 
The 9160 should be situated away from the path of vehicles and free from water or dust spray. The 9160 
should only be mounted in the upright position, as shown in Figure 1 below. This orientation minimizes 
the risk of water entering the 9160, should the unit accidentally be sprayed.  
The 9160 is attached to a vertical surface using four fasteners on the rear plate (type of fasteners are 
dependent on mounting surface). The top two holes in the rear plate are slots, allowing the unit to be hung 
in position before the remaining bolts are installed. The bolts used for installation are SAE 1/4-20. 
Mounting Slot
Cable Tie Mount
Mounting Hole
 
Figure 1: 9160 Installation Position