Visonic Inc. DUO200E User Manual

Page of 4
DE1821 
 
DUO
 
200 
Dual-Technology Microwave/PIR Intrusion Detector 
 
Installation Instructions
 
1. INTRODUCTION 
DUO
 
200
 
is
 
a
 
state-of-the-art
 
microcomputer controlled dual- 
technology intrusion detector. Its operation is based on two 
physical phenomena - the infrared (IR) radiation emitted by the 
human body and the Doppler frequency shift caused by a person 
moving in a microwave (MW) field. The IR and MW technologies, 
when combined in a single detector, complement each other to 
assure the most reliable detection and immunity to false alarms. 
The superiority of the DUO 200 over other dual detectors has 
been achieved by the advent of the True Motion Recognition™ 
algorithm  (patented). This advanced motion analysis method 
provides the DUO 200 with the ability to distinguish between the 
true motion of a human body and any other disturbances which 
invariably cause false alarms. 
Another unique feature of the DUO 200 is the MW Motion 
Simulator
 circuit (patents applied for), which simulates the effect 
created by a human body moving in the MW field. The simulation 
routine is carried out periodically for self-testing, supervision and 
assurance that the MW detector operates properly. 
 
Figure 1. DUO 200 General View 
 
2. SPECIFICATIONS 
Input Voltage: 9 to 16 VDC 
Current Drain: About 23 mA @ 12 VDC  
PIR SECTION (see Figure 2) 
Detector:
 Low noise dual-element pyroelectric sensor 
Trip Indication: Green LED flashes for up to 5 seconds 
True Motion Event Verification Counter: Selectable, 1 or 2 
motion events 
Lens Data 
  No. of Beams: 34 
  Field of View: 90° 
 Max. 
Coverage: 
12 x 12 m (40 x 40 ft) 
Vertical Adjustment: +2° to –12°, by sliding the circuit board 
along a calibrated scale. 
MW SECTION 
Oscillator:
 Microstrip DRO-stabilized type 
Frequency: 2.45 GHz 
Detection Range: Adjustable from 25% to 100% (3 m to 12 m) 
Trip Indication: Green LED illuminates for up to 5 seconds 
ALARM, TAMPER & TROUBLE DATA 
Alarm Indication:
 Red LED illuminates for 1.3 to 5 seconds if 
both detectors trip 
Relay Contacts: Normally closed, 0.1 A resistive/30 VDC; 18 
Ω
 
resistor in series with contacts 
Alarm Duration: 1.3 to 5 seconds (red LED lights and output 
relay contacts open) 
Tamper Contacts: Normally closed, 0.1A resistive / 30 VDC
 
Trouble Output: Open-collector, 100 mA max., with 47 
Ω resistor 
in series  
PHYSICAL CHARACTERISTICS 
Dimensions (H x W x D):
 104 x 60 x 32 mm (2.4 x 4.1 x 1.3 in.) 
Weight: 80 g (2.8 oz) 
MOUNTING 
Direct:
 Surface or corner without bracket, up to 2.5 m (8 ft) 
 
Figure 2. PIR and MW Coverage Pattern  
ACCESSORIES (see Figure 4) 
BR-1:
 Surface mounted swivel bracket, adjustable 30° down and 
45° left/45° right.  
BR-2: BR-1 with a corner adapter (kit) 
BR-3: BR-1 with a ceiling adapter (kit) 
ENVIRONMENTAL CONDITIONS 
Operating Temperature: 
–10°C to 50°C (14°F to 122°F) 
Storage Temperature: –20°C to 60°C (–4°F to 140°F) 
RFI Protection: Greater than 30 V/m (20 MHz to 1000 MHz) 
PATENTS 
U.S. Patents:
 5,237,330 and 5,693,943; Des. 346,567 
Compliance with Standards: EN 50131-1 Grade 2 Class II 
 
ATTENTION! Detection occurs only in areas in which the MW and PIR patterns overlap