Panic Button (PB-23)
 
The Panic Button is used to activate (or deactivate) a panic alarm. 
Parts Identification 
 
1. LED 
Indicator 
The LED indicator will light up briefly when the device is transmitting a signal. 
2. Panic 
Button 
1.  Press to send a learn code or activate a panic alarm 
2.  Press and hold the button for 8 seconds to send a Cancel Code to the Control Panel. (This   
function is not compatiable with every control panel). 
3. Battery 
Compartment 
4.  4 x Cover-Fixing Screws   
5. Battery 
Insulator 
Battery 
The Panic Button is powered by one CR123A 3V Lithium battery. 
The Panic Button will transmit any detected low battery status along with any regular status 
signal transmission to the Control Panel for display accordingly.   
When changing battery, after removing the old battery, press the button twice to fully discharge 
before inserting new battery. 
Supervisory Signal 
The Panic Button will automatically transmit Supervisory Signals every 30 to 50 minutes. 
If the Control Panel has not received the signal from the Panic Button for a preset period of time, 
the Control Panel will indicate that the Panic Button is out-of-signal range or is out of order. 
Getting Started 
Pull out the Battery Insulator to power on the Panic Button 
Put Control Panel into learn mode 
Press the button on the Panic Button to transmit a learn code. 
Refer to your Control Panel’s operation manual to complete the learn-in process. 
Walk Test 
Place the Control Panel in the walk test mode. 
Press the Button once. 
The Panel will display the RSSi (Radio Strength Signal) strength.