Codan Radio Communications UT-3-460-S08 User Manual

Page of 159
DE
DANIELS
ELECTRONICS
3-6
UHF Amplifier Instruction Manual UT-3 406 - 512 MHz
5
Put the 50 ohm load back on again.  The voltmeter should read approximately 0 Vdc.
6
Disconnect the voltmeter.
3.6.2.5
Antenna VSWR Overload
1
Disconnect the radio communications test set and so that the amplifier is terminated
with an open circuit.
2
Monitor the current from the +9.5 Vdc supply.
3
Adjust R38, the VSWR  overload adjustment, clockwise until a noticeable drop in the
+9.5 Vdc current occurs.
4
Reconnect the radio communications test set and, the +9.5  Vdc current should return
to the previous level.
3.6.2.6
Procedure Verification
1
Verify that the current drawn from the +13.8 Vdc supply is less than 1.5 A and from
the +9.5 Vdc supply is less than 1.2 A when transmitting full 8 W RF output power.
2
Turn off the power to the transmitter.