UT-4R400 UHF Project 25 Digital Transmitter Instruction Manual
3-3
measured by the frequency counter matches the test frequency displayed on the screen to within +/-
150 Hz.  Click on the "UPDATE SOFTPOT" button to save the setting in the transmitter's  non-
volatile memory.  This completes the adjustment of the reference oscillator.  Leave the Transceiver
RF Board disconnected from the amplifier module and continue with the next alignment procedure.
3.4.4
 
Transmitter Deviation Balance Adjustment
This adjustment equalizes  the  modulation  sensitivity  of  the  low  and  high  frequency modulation
paths on the Transceiver RF  board.   To perform  the  adjustment,  disconnect  the  Transceiver  RF
Board from the amplifier module by separating the SMB connectors.  Connect the RF  output cable
of the Transceiver  RF  board  to  a  communications  test  set.    Connect the  transmitter  to  an  IBM
compatible computer using the Programming Cable.  Apply power to the transmitter and  run  the
Radio Programming Software.   Navigate to the TRANSMITTER \ SERVICE TRANSMITTER \
DEVIATION BALANCE screen, where you will see a list of test frequencies and current SoftPot
values for each frequency.  Select the radio button next to the first test frequency and click on the
"LOW  PTT"  button.    This  causes  an  internally  generated  80  Hz  tone  to  be  applied  to  the
modulator.    Note  the  deviation  of  the  carrier  on  the  communications  test  set,  and  click  on  the
"HIGH PTT" button.  This causes a 3 kHz tone to be applied to the modulator.  Adjust the slider
next to the test frequency until the measured deviation matches that of the 80 Hz tone.   Now  click
on the "LOW PTT" button again to check the deviation.    If  the  deviation  has  changed from  the
original reading, note the new deviation and perform the adjustment at the high frequency again.  It
may require several iterations of this process to get the deviations to match within +/- 2%.  When
the  deviations  match,  click  on  the  "UPDATE  SOFTPOT"  button  to  save  the  setting  in  the
transmitter's non-volatile memory.  Repeat the adjustment process for each of the test frequencies.
Leave the Transceiver RF  Board disconnected  from  the  amplifier  module and  continue  with  the
next alignment procedure.
3.4.5
 
Transmitter Deviation Limit Adjustment
This adjustment prevents over deviation of the transmitter's  carrier.  To  perform  the  adjustment,
disconnect  the  Transceiver  RF  Board  from  the  amplifier  module  by  separating  the  SMB
connectors.  Connect the RF  output cable of the Transceiver RF  board to  a  communications  test
set.  Connect the transmitter to an IBM compatible computer using the Programming Cable.  Apply
power  to  the  transmitter  and  run  the  Radio  Programming  Software.    Navigate  to  the
TRANSMITTER  \  SERVICE  TRANSMITTER  \  ADJUST  DEVIATION  LIMITS  menu  item,
where you will see a list of test frequencies and current SoftPot values for each frequency.  Select
the radio button next to the first test frequency and click on the "ENABLE TX"  button to key the
transmitter.  Adjust the slider next to the selected test frequency under the measured deviation  of
the carrier is between 2785 Hz and 2885 Hz.  Click on the "UPDATE SOFTPOT" button to save
the new setting to the radio's non-volatile memory.  Repeat the process  for  each test  frequency.
This  completes  the  adjustment  process  for  the  transmitter  deviation  limits,  and  completes  the
alignment process for the Digital Signal Processor Board.  
3.4.6
 
Audio Level Alignment
The  audio  level  should  be  set  after all other  alignments  have  been  completed.   The  transmitter
should be programmed to an analog channel for the purposes  of the test,  since the vocoder in the
transmitter  encodes  pure  sine  signals  with  a  large  amount  of  distortion.    The  transmitter’s
Unbalanced Audio input (at P1-Z18) should be connected to an audio  signal  generator  set  up  to
deliver a 1 kHz tone at a level of 308 mVRMS (-8 dBm in a 600 ohm system).   The RF  output of
the transmitter should be connected to a service monitor set to monitor the deviation of the carrier