Codan Radio Communications VT-3-150-SN User Manual

Page of 262
1-2
VHF Amplifier Instruction Manual VT-3 132 - 174 MHz
Transmitter Mismatch Protection:
20:1 VSWR at all phase angles.
Transmitter Alarm:
Forward power sense and reverse VSWR;
- open collector output (separate or 'OR'ed configuration);
-linear output (separate lines only).
Operating Temperature Range:
-30˚ C to +60˚ C, optional -40˚ C temperature test.
Operating Humidity:
95% RH (non-condensing) at +25˚ C.
Operating Voltage:
+13.8 Vdc Nominal (range +11 to +16 Vdc),
+9.5 Vdc Regulated.
Transmit Current:
0.7 Amp typical;  1.1 Amp maximum
Amplifier Standby Current:
less than 0.5 mA.
Amplifier Enable:
Active to ground.
Amplifier Enable Response:
typically overdamped, rising to within 90% of full power 
within 5 msec; maximum (underdamped) overshoot of 30%.