Codan Radio Communications VT-3-150-SN User Manual

Page of 262
VHF Amplifier Instruction Manual VT-3 132 - 174 MHz
2-3
2.5
Power Sensing Circuitry
The VT-3/150 Amplifier is equipped with  output  power and  VSWR  sensing  lines  which  can  be
individually configured as  open  collector  or  linear  outputs.    In  open  collector  configuration,  the
output is active low, that is, when a fail condition is detected (not enough output power or too high
antenna  VSWR)  the  open  collector  transistor  is  turned  on.    In  linear  configuration,  a  voltage
proportional to the sensed output power or antenna VSWR is output.
Both the Output Power Alarm setpoint and the VSWR  Alarm setpoint are individually adjustable;
however,  the  Output  Power  Alarm  setpoint  must  always  be  adjusted  before  the  VSWR  Alarm
setpoint.  This is because the Output Power Alarm setpoint is used as a reference  by  the  VSWR
Alarm circuitry.
2.5.1
Output Power Sense
The  output  power sense  circuitry  uses  directional  coupler TL2  to  sample  some  of  the  forward
power.   The  sampled power is  rectified  by  diode  D6  and  capacitor  C20  and  then  amplified  by
op-amp U3b.   Op-amp U3b's  amplification  is  controlled  by  R21,  the  output  power alarm  adjust
potentiometer.  The amplified voltage is then output directly in linear operation (JU1  installed, JU2
not  installed)  or  compared  by  op-amp  U1a  which  then  drives  transistors  Q4  and  Q3  for  open
collector operation (JU1 not installed, JU2 installed).
In  open  collector  configuration,  Q3  (the  open  collector  output  transistor)  is  turned  on  when  an
alarm condition occurs.  The adjustment range for the output power alarm can vary depending on
the setting of R21 (the Output Power Alarm Adjust potentiometer).
2.5.2
VSWR Sense
The VSWR  sense circuitry uses  directional  coupler TL3  to  sample some  of  the  power reflected
from the antenna terminal.  The reflected power is rectified by diode D7 and capacitor C25 and then
amplified by op-amp U2b.   Op-amp U2b's  amplification is controlled by R36, the  VSWR  Alarm
Adjust  potentiometer.    The  amplified  voltage  is  then  output  directly  in  linear  operation  (JU4
installed, JU3 not installed) or compared to the output power alarm setpoint by op-amp U3a which
then drives transistor Q5 for open collector operation (JU4 not installed, JU3 installed).
In  open  collector  configuration,  Q5  (the  open  collector  output  transistor)  is  turned  on  when  an
alarm condition occurs.  The adjustment range for the VSWR  Alarm can depending on the setting
of R36 (the VSWR Alarm Adjust potentiometer).