Codan Radio Communications VT-3-150-SN User Manual

Page of 262
Enhanced AM/FM Synthesizer Instruction Manual OS(R/T)-3(A/H) 29 - 470 MHz
3-5
unlocked  operation
.   
The  tuning  range  capability  of  all  synthesizer  models  is  listed  in  the
Specifications section (1.3) of this manual.
3.5.5.2
 
VHF OS(R/T)-3A 118 - 159.4 MHz Alignment
Refer to the 
"OS(R/T)-3A 118 - 159.4 MHz  Analog Board Component Layout"
  diagram  and  the
"OS(R/T)-3A 118 - 159.4 MHz  Analog Board Schematic Diagram"
 
on pages 4-5, 4-6 and 4-7 of
this manual.
Using a high impedance (10 M
Ω
) DC  Voltmeter, measure the PLL control voltage at TP4 located
on the synthesizer module analog board (top)
.  
Access to TP4 is available through the synthesizer
top  cover
  VHF  synthesizers  operating  in  the  118 - 159.4 MHz  frequency  range  require  no
frequency adjustment as tuning is microprocessor controlled.  (The OST-3A128 and OSR-3A149,
covering  118-138 MHz  and  139.4 - 159.4 MHz  respectively,  provide  full  band  coverage  without
tuning adjustment.)
All  channel  selections  should  result  in  a  TP4  voltage  between  +3.1  and  +3.5 Vdc
.   
Channel
selections beyond the tuning range capability of the synthesizer will  result  in  unlocked operation
over the temperature range -40C to +60C
.  
The tuning range capability of all synthesizer models is
listed in the Specifications section of this manual.
3.5.5.3
 
VHF OS(R/T)-3H 128 - 174 MHz VCO Alignment
Refer  to  the 
"OS(R/T)-3H  128 - 174 MHz  Analog  Board  Component  Layout"
  diagram  and  the
"OS(R/T)-3H 128 - 174 MHz Analog Board Schematic Diagram"
 on pages 4-9, 4-10 and 4-11 of
this manual.
Using a high impedance (10 M
Ω
) DC  Voltmeter, measure the PLL control voltage at TP4 located
on the synthesizer module analog board (top).  Access to TP4 is available through the synthesizer
top  cover.    Using  a  small  standard  blade screwdriver,  carefully  adjust  the  VCO  fine  frequency
"TUNE"  trimmer  capacitor  C24  until  a  test  point  (TP4)  voltage  of  approximately  +2.3 Vdc  is
obtained.    Measured  PLL  loop  control  voltages  below  approximately  +0.5 Vdc  and  above
approximately +4.5 Vdc will indicate an "out of lock" synthesizer condition.
It is important to check the loop control voltage at  TP4  when multiple  synthesizer channels have
been  programmed.    All  channel  selections  should  result  in  a  TP4  voltage  within  the  +1.0  to
+4.0 Vdc  range.    Adjust  the  fine-tuning  capacitor  C24  to  center  multiple  channel  voltages
symmetrically  about  +2.3 Vdc.  Channel  selections  beyond  the  tuning  range  capability  of  the
synthesizer will result in unlocked operation.  The tuning range capability of all synthesizer models
is listed in the Specifications section of this manual.