Codan Radio Communications VT-3-150-SN User Manual

Page of 262
3-10
Transmitter Main Board Instruction Manual
3.10 MT-3 Audio Processor Alignment (Version 1.8)
invisible text
3.10.1General
Verify the standard factory settings for the MT-3 Audio Processor  as given in section 3.9.1 before
beginning the  standard  deviation  adjustment  procedure.    If  the  transmitter's  channel  frequency
changes, the audio processor should be realigned to optimize  the  transmitter's  performance.    The
schematic diagram for the audio processor is shown in section 5.5.2 and the component layout is
shown in section 5.5.1.
3.10.2MT-3 Audio Processor Standard Deviation Adjustment
Note:  clockwise rotation of controls increases signal levels.
1
Connect  the  transmitter  to  the  radio  communications  test  set  and  monitor  FM
deviation,  distortion,  and  audio  frequency.    Before  adjusting  the  audio  deviation,
confirm that the transmitter RF output frequency is correct.
2
Connect the 600 ohm input to  the  incoming  audio  (pins  B18,  Z18).    Set  the  audio
frequency to 1 kHz at the desired level of -8 dBm.
3
Increase  the  balance  level  control  (R31)  so  that  the  deviation  increases  until
compression is observed.
4
Adjust  the  compression  control  pot  (R38)  for  compression  at  ±60%  maximum
deviation.
5
Set  the  audio  frequency  to  2.4  kHz,  then  adjust  the  deviation  control  (R29)  for
maximum deviation.
6
Reset  the  modulating  frequency to  1  kHz  and  re-adjust R38  for  ±60%  maximum
deviation.
7
Repeat steps 4 and 6 until both conditions are met.
8
Vary the audio signal from 1 kHz to 3 kHz  and  measure the  positive  deviation  and
then the negative deviation.  Adjust the symmetry control (R14) until the ± deviation is
symmetrical.  The variation between ± deviation levels should not exceed 300 Hz over
the 1 kHz to 3 kHz range.
9