Codan Radio Communications VT-3H040-S-HSO User Manual

Page of 50
 
DANIELS
ELECTRONICS LTD.
TM
1-2 
IM20-VT3040AMP      VT-3H040 VHF Amplifier Instruction Manual 
 
Harmonic Emissions:   
 
Greater than 80 dB below the carrier. 
 
Spurious Emissions:   
 
Greater than 90 dB below the carrier. 
 
Transmitter Mismatch Protection: 
20:1 VSWR at all phase angles. 
 
Transmitter Alarm:   
 
Forward power sense and reverse VSWR; 
 
 
 
 
 
 
- open collector output (separate or 'OR'ed configuration); 
 
 
    -linear 
output 
(separate 
lines 
only). 
 
Operating Temperature Range: 
-30˚ C to +60˚ C, optional -40˚ C to +60°C temp test. 
 
Operating Humidity:   
 
95% RH (non-condensing) at +25˚ C. 
 
Operating Voltage:   
 
+13.8Vdc Nominal (range +11 to +16Vdc), 
 
 
    +9.5Vdc 
Regulated. 
 
Amplifier Transmit Current:   
0.7 Amp typical; 1.1 Amp maximum 
 
Amplifier Standby Current:   
less than 0.5 mA. 
 
Amplifier Enable: 
 
 
Active to ground. 
 
Amplifier Enable Response:   
typically overdamped, rising to within 90% of full power 
 
   
 
 
 
within 5 msec; maximum (underdamped) overshoot of 
30%.