GatesAir Inc. CZF User Manual

Page of 148
 
  
APEX
 Exciter Incorporating FLO
 Technology
Navigating the LCD Display Screens
Details of the Exciter Status Screens
Page: 3-14
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
3.4.4.3
FLO FPGA Status, Summary, Screen 1/5
FPGA Status1.bmp
Figure 3-12  FLO FPGA Status, Summary, Screen 1/5
The parameters of the FPGA Summary screen are as follows.
• FPGA Version:
• TS input: Indicates the active transport stream (TS1 Active or TS2 Active) if one or 
both streams are connected to the two ASI inputs on the exciter rear panel. 
The presence of one or both of the transport streams in indicated in the TS1 and TS2 
Detect indications of the Transport Stream Status screen (screen 3/5 in this series of 
screens).
In both transport streams are missing, the indication Inactive (in red) appears.
• SFN Error: YES (in red) indicates error, NO (in black) indicated OK
• RF Mute: YES (in red) indicates mute, NO (in black) indicated OK
• Fatal Error: YES (in red) indicates error, NO (in black) indicated OK
• FPGA Reset: This is an indication of the number of times the FPGA has been reset.