(2) Changing SWDIP switch settings 
 
 
When the message shown at the following is printed in the function setting mode, 
press the POWER switch. 
Load Default Setting? 
Yes: Feed SW / No: Power SW 
 
HINT 
  There are SWDIP switches from 1 to 4 in the printer, so set 8 bits within 
SWDIP switches respectively. 
  In function setting mode, the POWER lamp blinks once by pressing 
either the POWER switch or the FEED switch.  Be sure to confirm the 
POWER lamp blinking in order to ensure proper operation. 
 
Operation 1: SWDIP switch selection 
  If pressing the FEED switch when the message shown at the following is 
printed, the function setting mode goes to operation (2). 
 
If pressing the POWER switch instead of the FEED switch, the details of the 
printed SWDIP switch (SWDIP switch 1) are not changed, and the next 
SWDIP switch is selected (operation 1). 
DIP Switch setting mode. 
DIP SW-1=********  
Change Setting? 
Yes: Feed SW / No: Power SW 
 
HINT 
  "********" in the message indicates the setting of the SWDIP switch.  The 
leftmost bit is the most significant bit (SWDIP*-8) and the rightmost bit is 
the least significant bit (SWDIP*-1). 
  If SWDIP switches 1 to 4 are skipped, the function setting mode can be 
terminated (operation 3).