Control Loop Error. If the cartesian control loop goes
out of limits, for example, due to low supply volts, the
output power gradually reduces by up to 3 dB until the
loop regains stability. If this fails to stabilise the loop the
transmitter de-keys and a BIT alarm is indicated.
Harmonic outputs
Harmonic outputs are below -36 dBm.
ENVIRONMENTAL
Temperature range
The transmitter operates to specification at temperatures
between -20 and +55
°
C and at a relative humidity
between 5% and 90% (non-condensing).
Duty cycle
100%.
Warm up time
The transmitter is fully operational 5 seconds after
switch on.
Storage
The transmitter can be stored at temperatures between
-30 and +70
°
C without causing damage.
Cooling
The transmitter has an integral cooling fan.
POWER REQUIREMENTS
The transmitter operates from an ac input supply, or a dc input supply. When both supplies are
connected, the dc input acts as an automatic backup supply for the ac mains.
ac input supply
The transmitter operates from a 48 to 62 Hz
single-phase ac supply.
The input voltage, measured at the equipment, can be
110/120/220/230/240 V ac (± 10%). The correct ac
input tap must be selected to suit the input voltage.
Additionally, the correct ac input fuse F2 must be fitted.
See installation detail on page 23.
ac power consumption
Typically 330 VA. 500 VA maximum.
dc input supply
Between 21.6 and 32 V. Full output power capability is
maintained with a dc input between 24 and 32 V. From
24 down to 21.6 V the output power gradually
decreases.
dc supply current
15 amp (maximum) with a 28 volt dc input supply.