system ComPonents
3.4 Accessory Devices continued
1161 Residential Smoke Detector Residential smoke detector with sounder.
1162 Residential Smoke Detector Residential smoke/heat detector with sounder and fixed rate-of-rise heat detector
Keypads
ePAD™ Virtual Keypads
1162 Residential Smoke Detector Residential smoke/heat detector with sounder and fixed rate-of-rise heat detector
Keypads
ePAD™ Virtual Keypads
Allows users to control the security system from any computer in the world using the
Internet.
LCD keypads
Allows you to control the panel from various remote locations. Connect up to five keypads.
Model 690, 790, 693/793 Security Command™ keypads, 7060, 7063, 7070, 7073, 7160, 7163,
7170, 7173 Thinline™ keypads, 7060A, 7063A, 7070A, 7073A Aqualite™ keypads, 7360, 7363
Thinline Icon Series keypads, or 7760 Clear Touch™ keypad to the keypad bus using terminals
7, 8, 9, and 10.
Cellular Antennas
383 Rubberduck Stub Antenna
383 Rubberduck Stub Antenna
Provides SMA Rubberduck Antenna for cellular connection.
384 Magnetic Mount Antenna
Provides SMA Magnetic Mount Antenna for cellular connection.
385 Dual Band Smartdisc Antenna Provides SMA Dual Band Smartdisc Antenna for cellular connection.
3.5 XT30/XT50 Wiring Diagram
16 to 18
gauge wire
Maximum AC
Wire distance ñ
16 gauge wire: 70 feet
18 gauge wire: 40 feet
RED
BLACK
Cold Water
Pipe Earth
Ground
s
s
s
s
USE MARKING
Commercial Burglary Control Unit (DACT)
Household Fire and Burglary Warning System
Control Unit.
NFPA 72
This equipment should be installed in accordance with Chapter 11
of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National
Fire Protection Association, Batterymarch Park, Quincy, MA
02269). Printed information describing proper installation,
operation, testing, maintenance, evacuation planning, and repair
service is to be provided with this equipment. Warning: Ownerís
instruction notice, not to be removed by anyone except occupant.
HOUSEHOLD FIRE WIRING
Recognized limited energy cable must be
used for connection of all initiating,
indicating, and supplementary devices.
POWER LIMITED
All circuits on the Model XT30/XT50 comply
with the requirements for inherent power
limitation and are Class 2.
TYPES OF SERVICE
Suitable for DACT Central Station.
Suitable for Household Fire and
Suitable for Household Fire and
Household Burglary. Test weekly.
SIA CP-01-2007 minimum system is
SIA CP-01-2007 minimum system is
XT30 or XT50, local Bell, and off premise
DACT communication to an
SCS-1R receiver plus ANSI/SIA CP-01-
2007 classified compatible DMP keypads
as indicated in the installation guide.
J3
Phone Line
Outputs
J11
1
2
3
4
J1
Ethernet
J16
Reset
J20
Wireless
Antenna
connection
J7 RJ
Supervision
J19 Celllular
Antenna
connection
XT30/XT50
Command Processorô Panel
RED
PROG
J8
Programmer Header J8
Use DMP Model 330 Harness
AC Wiring must be in conduit and exit out
the left side of the enclosure.
Wiring on terminals 5 through 26 must exit
right and maintain a 1/4" separation from
the AC and battery positive wiring.
Terminals 5-20 are Power Limited.
Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
Plug into
120 VAC
60 Hz
outlet not
controlled
by switch.
Zone 10 compatibility
identifier: A
Maximum operating
range:
8.8 VDC - 14.2 VDC.
DMP Transformers
Model 321 ñ 16.5 VAC 40 VA
Class 2 plug-in.
Class 2 plug-in.
Model 320 ñ 16.5 VAC 40 VA
Class 2 wire-in.
Verification
Zone
10
Control Unit
Delay
13.6 sec.
Smoke
Model
______
Detector
Delay
____sec.
Heat detectors, manual pull stations, or any other
shorting device. Unlimited number of units.
1K Ohm EOL
on each zone
3.3K Ohm EOL
Switched
Voltage
Output
Zone 10
Keypad
Bus
Smoke
Zones 1 to 9
Bell
Secondary Power Supply
1.2 Amps maximum charging current. Use only
12 VDC rechargeable batteries. Replace every 3
to 5 years.
Minimum voltage on
Auxiliary output to
process Sensor trips
is 10.4 VDC.
For Wireless Devices, Control Unit delay is 0 (zero).
Bell ó 10.2 - 13.9 VDC
Total current: 1.5 Amps max.
w/ 40 VA
AUX (RED) ó Up to 500mA
auxiliary current at 10.2 -
13.9 VDC from Terminal 7
Smoke Output: ó 100mA at
10.2 - 13.9
VDC Terminal 11
Smoke
Detector
1k Ohm
s
s
To Keypad
or Zone
Expander
For NRTL listed applications the maximum current from a combination of
bell output, auxillary output, and smoke output is 1.6 amps.
Figure 1: System Wiring Diagram