XT30/XT50 Installation Guide
4
system ComPonents
3.4  Accessory Devices continued
1161 Residential Smoke Detector Residential smoke detector with sounder.
1162 Residential Smoke Detector Residential smoke/heat detector with sounder and fixed rate-of-rise heat detector
Keypads
ePAD™ Virtual Keypads
Allows users to control the security system from any computer in the world using the 
Internet.
LCD keypads
Allows you to control the panel from various remote locations. Connect up to five keypads.
Model 690, 790, 693/793 Security Command™ keypads, 7060, 7063, 7070, 7073, 7160, 7163,
7170, 7173 Thinline™ keypads, 7060A, 7063A, 7070A, 7073A Aqualite™ keypads, 7360, 7363
Thinline Icon Series keypads, or 7760 Clear Touch™ keypad to the keypad bus using terminals
7, 8, 9, and 10.  
Cellular Antennas
383 Rubberduck Stub Antenna
Provides SMA Rubberduck Antenna for cellular connection.
384 Magnetic Mount Antenna
Provides SMA Magnetic Mount Antenna for cellular connection.
385 Dual Band Smartdisc Antenna Provides SMA Dual Band Smartdisc Antenna for cellular connection.
3.5  XT30/XT50 Wiring Diagram
16 to 18 
gauge wire
Maximum AC 
Wire distance ñ
16 gauge wire: 70 feet
18 gauge wire: 40 feet
RED
BLACK
Cold Water 
Pipe Earth 
Ground 
s
s
s
s
USE MARKING
Commercial Burglary Control Unit (DACT)
Household Fire and Burglary Warning System 
Control Unit.
NFPA 72
This equipment should be installed in accordance with Chapter 11 
of the National Fire Alarm Code, ANSI/NFPA 72-2002, (National 
Fire Protection Association, Batterymarch Park, Quincy, MA 
02269). Printed information describing proper installation, 
operation, testing, maintenance, evacuation planning, and repair 
service is to be provided with this equipment. Warning: Ownerís 
instruction notice, not to be removed by anyone except occupant.
HOUSEHOLD FIRE WIRING
Recognized limited energy cable must be 
used for connection of all initiating, 
indicating, and supplementary devices.
POWER LIMITED
All circuits on the Model XT30/XT50 comply 
with the requirements for inherent power 
limitation and are Class 2.
TYPES OF SERVICE
Suitable for DACT Central Station. 
Suitable for Household Fire and 
Household Burglary. Test weekly.
SIA CP-01-2007 minimum system is 
XT30 or XT50, local Bell, and off premise 
DACT communication to an 
SCS-1R receiver plus ANSI/SIA CP-01-
2007 classified compatible DMP keypads 
as indicated in the installation guide.
J3
Phone Line
Outputs
J11
4
J1
Ethernet
J16
Reset
J20
Wireless 
Antenna 
connection
J7 RJ 
Supervision
J19 Celllular 
Antenna 
connection
XT30/XT50
Command Processorô  Panel
RED
PROG
J8
Programmer Header J8 
Use DMP Model 330 Harness
AC Wiring must be in conduit and exit out 
the left side of the enclosure.  
Wiring on terminals 5 through 26 must exit 
right and maintain a 1/4" separation from 
the AC and battery positive wiring.  
Terminals 5-20 are Power Limited.
Listed Resistors
1.0k Ohm - DMP Model 311
3.3k Ohm - DMP Model 309
Plug into 
120 VAC 
60 Hz 
outlet not 
controlled 
by switch.
Zone 10 compatibility 
identifier: A
Maximum operating 
range: 
8.8 VDC - 14.2 VDC.
DMP Transformers
Model 321 ñ 16.5 VAC 40 VA 
Class 2 plug-in.
Model 320 ñ 16.5 VAC 40 VA 
Class 2 wire-in.
Verification 
Zone
10
Control Unit 
Delay 
13.6 sec.
Smoke 
Model
______
Detector
Delay
____sec.
Heat detectors, manual pull stations, or any other 
shorting device. Unlimited number of units.
1K Ohm EOL
on each zone
3.3K Ohm EOL
Switched 
Voltage 
Output
Zone 10
Keypad
Bus
Smoke
Zones 1 to 9
Bell
Secondary Power Supply
1.2 Amps maximum charging current.  Use only 
12 VDC rechargeable batteries.  Replace every 3 
to 5 years.
Minimum voltage on 
Auxiliary output to 
process Sensor trips 
is 10.4 VDC.
For Wireless Devices, Control Unit delay is 0 (zero).
Bell ó  10.2 - 13.9 VDC
Total current: 1.5 Amps max. 
w/ 40 VA
AUX (RED) ó  Up to 500mA 
auxiliary current at 10.2 - 
13.9 VDC from Terminal 7
Smoke Output: ó  100mA at 
10.2 - 13.9
 VDC Terminal 11
Smoke 
Detector
1k Ohm
s
s
To Keypad 
or Zone 
Expander
For NRTL listed applications the maximum current from a combination of 
bell output, auxillary output, and smoke output is 1.6 amps.
Figure 1: System Wiring Diagram