Transmitter Supervision Time
For NRTL Listed installations, program the transmitter supervision time in panel zone programming as listed in the 
following table.  Refer to the XRSuper6/XR20/XR40 Programming Guide (LT-0305) for complete wireless programming 
information.
UL Listing
Listed Accessories
Supervision 
Time
ANSI/UL  1023  Household Burglary Alarm System Units 
 
 
Accessory
1101/1102/1103 Universal Transmitters
1125 PIR Motion Detector
1142 Two-Button Hold-Up Transmitter
60
60
60
ANSI/UL  636  Holdup Alarm Units and Systems Accessory 1142 Two-Button Hold-Up Transmitter
60
ANSI/UL  634  Connections and Switches for use with 
Burglar Alarm Systems Accessory
1101/1102/1103 Universal Transmitters
60
ANSI/UL  639  Intrusion Detection Units Accessory
1125 PIR Motion Detector
60
ANSI/UL  365  Police Station Connected Burglar Accessory 1103 Universal Transmitter
60
ANSI/UL  609  Local Burglar Alarm Units and System 
Accessory
1103 Universal Transmitter
60
ANSI/UL  1076  Proprietary Burglar Alarm Units Accessory
1103 Universal Transmitter
60
ANSI/UL  1610  Central Station Burglar Alarm Units 
Accessory
1103 Universal Transmitter
60
ANSI/UL  985  Household Fire Warning system Accessory
1101/1102/1103 Universal Transmitter
1161/1162 Residential Smoke Detectors
3
3
Receiver/Panel Software Version Table
The table below provides a list of the required panel and wireless receiver software versions needed to support each 
transmitter.  In each case the version must be the level indicated or higher.
Model
Description
1100DI 
Receiver
XRS6/XR20/XR40 
Panel
1101
Universal Transmitter, Internal/External Contacts
100
300
1102
Universal Transmitter, External Contact
100
300
1114
Four Zone Expander
100
300
1116
Relay Output
104
304
1117
LED Annunciator
104
304
1118
Remote Indicator Light
104
304
1121
PIR Motion Detector
100
300
1125
PIR Motion Detector
100
300
1129
Glassbreak Detector
100
300
1139
Wireless Bill Trap
100
300
1142
Two-Button Hold-Up Transmitter
100
300
1145, 1146, 1147 Four, Two, or One-Button Key Fobs
100
302
1161, 1162
Residential Smoke Detector
100