Wireless Bus Connection
The 1100XH easily interfaces with the XR500 Series Command Processor™ panels and XR100 Series Command 
Processor™ panels using the on-board DMP Wireless Bus connection (J22).  
Note: The 1100XH High Power Wireless Receiver cannot operate if connected to the Keypad Bus.
Harness Connection
Refer to Figure 2, the XR500 Series Installation Guide (LT-0681), the XR500 Series Programming Guide (LT-0679), the 
XR100 Series Installation Guide (LT-0899), the XR100 Series Programming Guide (LT-0896), and use the following steps 
to connect the panel and receiver:
1. Install a jumper across the header pins next to the letter “X” on the XR100/XR500 panel J23 header to enable 
on-board DMP Wireless operation. 
2. Connect the J4 header on the 1100XH to the XR100/XR500 panel J22 LX header.  
3. After power-up, briefly reset the panel using the J16 jumper to activate wireless zone operation. 
4. In System Options, program the House Code (1-50).  In Zone Information, program the wireless zones. 
��
��
��
�� ��
��
�� ��
��
���� ���
��� ���
��� ��� ��� ���
��
��
��
��
��
���
��
��
��������
��������
���
����
��
��������
�����
���
���
������
������
���
��
����
����
���
��
�������������������
�������������������
�����
�����
�����
������
���
����������������
����������������
��������������
�������
��������
���
���������������
���
��������������
���
���
�����
�������������
��������������
������
����������
�����������
��
��
���
Figure 2: XR100 or XR500 DMP Wireless Bus Connection
1100XH Receiver Operation
The 1100XH receiver automatically sends the panel house code to wireless transmitters when the unique transmitter 
serial number is programmed into the panel.  The house code identifies the panel, receiver, and transmitters to each 
other.  The receiver only listens for transmissions using the specified house code and/or programmed transmitter 
serial number.  
Note: When setting up a wireless system, it is recommended to program zones and connect the receiver before 
installing batteries in the transmitters.
Transmitters can be programmed for supervised or unsupervised operation.  When programmed as supervised, the 
transmitter must communicate with the receiver within the programmed number of minutes.  If the transmitter fails 
to communicate, the panel displays a missing condition.
Note:  When a receiver is installed, powered up, or the panel is reset, the supervision time for transmitters is reset.  
If the receiver has been powered down for more than one hour, wireless transmitters may take up to an additional 
hour to send a supervision message unless tripped, tampered, or powered up.  This operation extends battery life for 
transmitters. A missing message may display on the keypad until the transmitter sends a supervision message.
When any wireless zone programming is changed in the panel, receiver zone programming is updated.  At that point, 
all wireless zones display as normal for approximately one minute, regardless of the actual state of the contact.