Digital Monitoring Products Inc PC0132 User Manual

Page of 22
14 
9800 Series Keypad Installation Guide
Accessing Keypad Diagnostics
If necessary, refer to Access the Options Menu earlier in this document.
KPD KPD  KPD
OPT DIAG RF    STOP
  Keypad Diagnostics (KPD DIAG)
This option displays Zone Test.
Z1  OPen 
Z2  OPen 
Z3  OPen 
Z4  OPen
  Zone Test
This option allows the keypads to display the current 
electrical status of the four protection zones. The status is 
shown as OPEN, SHRT, or OKAY.
Note: The Zone Test displays on other keypads without 
built-in zones, but is not operational.
InPuT WIeGAnD
  Input Wiegand
This option tests the internal and external reader input 
from proximity credentials. The display shows OKAY each 
time a good proximity read is received.
Exiting the Installer Options
Press the CMD key until the display returns to the Installer Options screen. Select 