Digital Monitoring Products Inc PC0136 User Manual
734W Installation Guide
Digital Monitoring Products
4
Version Display
When you connect the keypad to the 734W module, the version number and release
date display.
• Press keys 1, 2, 3, or 4 then the CMD key to show zone status of that zone.
• Press CMD key to enter the Diagnostic Menu.
• Press 6653 (PROG) then CMD to enter the Programming Menu.
Zone Status Display
The status of the entered zone number displays. To display another zone, enter the
zone number followed by the CMD key.
Diagnostic Menu
Select YES to display the Panel Communication Connect Status display. Select NO to
return to Version Display.
Connect Status
To display the connection status of the 734W to the panel, select any top row key.
Not Connected: The 734W cannot connect to the panel on the WiFi network.
Bad Passphrase: The passphrase programmed in the 734W device does not match the
passphrase programmed in the panel.
Device Not Programmed: The device number programmed in the 734W is not programmed as a
Device Number in the panel.
Duplicate Device: There is another device on the WiFi network with the same device number.
Transmit Time XXX: The speed in milliseconds in which the last message was sent and received
between the 734W and the panel.
Programming Menu
Press the CMD key to enter programming and display initialization options.
Initialization Options
These options can set the 734W module programming memory back to factory defaults
in preparation for programming. Press any select key to enter the initialization menu.
Initialization Communications
Select YES to initialize the communication options back to factory defaults. Select NO to
leave communication options unchanged.
Initialize Confirm Option
After selecting YES to clear the Communication settings, the 734W displays SURE? YES NO
for confirmation to clear the memory. This is a safeguard against accidentally erasing the
programming. No memory is cleared from the programming until you answer YES to the
SURE? option. Selecting NO leaves communication options unchanged.
Initialization Access
Select YES to initialize the Access Options back to factory defaults. Select NO to return to
the INITIALIZATION menu.
INITIALIZATION
SURE? YES NO
Initialize Confirm Option
After selecting YES to clear the Access Options, the 734W displays SURE? YES NO for
confirmation to clear the memory. This is a safeguard against accidentally erasing the
programming. No memory is cleared from the programming until you answer YES to the SURE?
option. Selecting NO leaves communication options unchanged.
734W
COMMUNICATION
Communication Menu
Press any select key to enter the Communication menu. Press the CMD key to advance to
the Access Options menu. Press the back arrow to display the 734W Initialization menu.
INITIALIZATION
ACCESS? NO YES
734W
VER vvv mm/dd/yy
734W DOOR
ZONE: 2 -OPEN
734W REX
ZONE: 3 -SHORT
CONNECT STATUS
NOT CONNECTED
CONNECT STATUS
CONNECT STATUS
BAD PASSPHRASE
CONNECT STATUS
CONNECT STATUS
DEVICE NOT PROG
CONNECT STATUS
XMIT TIME xxx mS
MENU? NO YES
CONNECT STATUS
DUPLICATE DEVICE
734W
ZONE: 1 -OKAY
CONNECT STATUS
INITIALIZATION
COMMS? NO YES
734W
INITIALIZATION
734W
PROGRAMMER
INITIALIZATION
SURE? YES NO