Digital Monitoring Products Inc PC0152 User Manual

Page of 4
INSTALLATION SHEET
1127C PIR Motion Detector
Description
1127C is an 1100 Series Wireless Wall Mount Curtain PIR. The Detection area is a 50’ x 10’curtain using a fresnel lens. 
The PIR includes a case tamper and functionality to allow sensor configuration from the control panel. DMP Exclusive 
Features include Sensitivity Adjustment, Pulse Count, Walk Test, & Disarm Disable.
Features
• Remote configuration from panel
• Excellent R.F.I. and noise immunity
• Adjustable sensitivity from panel programming
• Pulse count selection allows multiple triggers 
before an alarm is initiated
• Walk Test mode initiated from panel
• Disarm Disable operation to save battery life
• Installs up to 8’ wall height
Compatibility
• All DMP 1100 Series Wireless Receivers and panels
What is Included
The 1127C Series PIR Motion Detector includes the 
following:
• One PIR detector with DMP wireless transmitter
• Two CR123 batteries
• Zone name and number label
• Serial number label
Installation
For your convenience, an additional pre‑printed serial number label is included. Prior to installing the device, record 
the serial number or place the pre‑printed serial number label on the panel programming sheet. This number is 
required during programming. As needed, use the zone name and number label to identify a specific transmitter.
Selecting the Best Location (LED Survey Operation)
The PIR transmitter provides a survey capability to allow one person to confirm transmitter communication with the 
receiver while the cover is removed. The PIR transmitter PCB Red Survey LED turns on whenever the processor turns 
on to send data to the receiver then immediately turns off when the receiver acknowledgement is received and the 
processor shuts off. While in Walk Test mode, waving your hand in front of the PIR is a convenient way to send data 
to the receiver to confirm operation. The PIR 
circuit board LED lights to indicate motion 
and the Survey LED briefly lights to confirm 
communication.
When the transmitter does not receive an 
acknowledgement from the receiver, the 
transmitter Survey LED remains on for about 
8 seconds to let you know communication is 
not established. Relocate the transmitter or 
receiver until the Survey LED immediately 
turns off indicating the transmitter and 
receiver are communicating properly. If the 
transmitter is not programmed into the panel, 
the Survey LED does not operate properly.
Figure 1: Remove the Cover 
Cover Lock Screw
Figure 2: Detection Pattern