Digital Monitoring Products Inc PC0163 User Manual

Page of 40
CellComSL
 
Series Universal Communicator Installation and Programming Guide 
Digital Monitoring Products
5
applIcatIons
Applications
The CellComSL Series Communicator can be used in a variety of applications:
3.1 CID 
Dialer Connection
Directly connect the telco phone line (tip and ring) from the control panel to the CellComSL to capture Contact
ID messages that are based on the SIA communication standard
DC-05-1999.09-DCS. These messages are 
then formatted into a Serial 3 message and sent to a DMP Model SCS-1R or SCS-VR Receiver. Note: CID Dialer
Connection cannot be used when using Zone 4 Bell Connection.
3.2 
Zones 1 - 4 Input Connection
Connect each burglary control panel relay output to a CellComSL Series Communicator zone. For programming
purposes, the zone numbers are 1 - 4. (See Figure 10 for wiring details). An example of how you might use this
application: You can use a normally closed output on the burglary control panel to indicate a burglary alarm. The
CellComSL zone should be programmed with a zone name and zone type of Burg. When the output on the control
panel turns on and trips the CellComSL zone, a message will be sent to an SCS-1R or SCS-VR receiver at Central
Station. You could use the zone name programming to describe which control panel zone indicated a burglary.
Note: Zone 4 can only be used as a standard input zone when not programmed as zone type Auxiliary 2 (A2). See
Zone 4 Bell Connection.
Figure 9: CellComSL Series Wiring Diagram for Tip and Ring Connection
Use 18-22 AWG for 
Power Supply connection
Z3
 +
Z4
 +
Z4
 -
GN
D
12 VDC Aux. Output
+
-
Ground
 Control Panel 
The panel or separate power 
supply must be 12 Volt Regulated 
and Power Limited.  
Z1
 +
Z2
 +
RESET
S1
LOAD
S2
B
AT
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
J8
J26
J9
S1
S2
S3
1k ohm
1k ohm
1k ohm
1k ohm
MODEL 
CellComSLC
Figure 10: CellComSL Series Wiring Diagram for Zones 1 - 4
Use 18-22 AWG for 
Power Supply connection
CON
TROL PA
NEL TIP
CON
TROL PA
NEL RIN
G
12 VDC Aux. Output
+
-
Ground
 Control Panel 
The panel or separate power 
supply must be 12 Volt Regulated 
and Power Limited.  
Telephone 
Jack 
Connector
BELL -
BELL +
RESET
S1
LOAD
S2
B
AT
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
J8
J26
J9
S1
S2
S3
MODEL 
CellComSLC