Digital Monitoring Products Inc PC0163 User Manual

Page of 40
Digital Monitoring Products 
CellComSL
 
Series Universal Communicator Installation and Programming Guide
28
Appendix
Z-Wave Test Option
 This feature allows the installer to test CellComSLCZ communication with Z-Wave
devices. A successful test indicates a response from a device. Press any top row Select
key to view the Z-Wave Device List.
Press COMMAND to advance through each Z-Wave device and press any top row Select
key to begin the test on the device displayed.
The name of the device displays above the device number. The current number of 
successful communications followed by the total number of attempts displays to the 
right of the device number. The test stops after 99 attempts.
Press COMMAND to view the final number of successful communications.
Contact ID Recvd
This displays DTMF digits dialed from the burglary control panel.
Exiting the Diagnostics program
Press the COMMAND key until STOP displays. Press any Select key. The keypad returns to the Status List display.
18.3  Using the 984 Command Function
When not in the Programming Menu, the function 984 + COMMAND can be entered at the keypad, and a remote
options menu appears. This menu contains the following options:
CELL
The communicator allows you to perform a test on each component of the cellular communication paths. While
the Status List displays, enter 984 and press the COMMAND key. Press the Select key under
 CELL to allow the 
communicator to perform a Communication Status Test. The keypad displays
CELL IS BUSY if the modem is being 
tested from another keypad.
Upon entry of a Cellular path when prompted, the test runs and the results display on the keypad in the order
they were tested: MODEM OPERATING, IDENTIFIED,TOWER DETECTED, REGISTERED, CONNECT SUCCESS, and CELL
COM GOOD. Press COMMAND to advance through the results. When the test is complete you are returned to the
Status List. See the Diagnostic Functions section for a description of the Cellular Status results.
18.4  Using the Walk Test
The communicator provides a walk test feature that allows a single technician to test all the zones on the
system. Conduct the Walk Test within 30 minutes of resetting the communicator. The Walk Test automatically
ends if no zones are tripped for 20 minutes.
TEST IN PROGRESS displays at all keypads. When five minutes
remain, 
TEST END WARNING displays. If any areas are armed the Walk Test does not start and SYSTEM ARMED 
displays.
 
Walk Test
To conduct the Walk Test, reset the communicator by momentarily pressing the RESET
button. From the keypad, enter the code 8144. The keypad displays
WALK TEST. If 
the system is monitored , the system sends a System Test Begin report to the Central
Station. All programmed zones are included in the test.
 
Trip Counter for Walk Test (STD)
Displays the number of zone trips during the Walk Test.
•  Each time a selected zone trips, the keypad buzzes.
END - Press the Select key directly below END to stop the Walk Test. When the Walk Test
ends or a 20 minute time-out expires, a final Sensor Reset occurs. The System Test End
message is sent to the receiver along with Verify and Fail messages for each zone under 
test. Faulted zones then display on the keypad.
 
Test End Warning
When no zones have been tripped and five minutes remain on the 20 minute Walk Test
timer, the keypad displays TEST END WARNING and the keypad tones. If no additional
test zone trips occur, the test ends and a final Sensor Reset automatically occurs. The
System Test End message is sent to the receiver along with Verify and Fail messages for
each zone under WALK test. Faulted zones then display on the keypad.
 
Failed Zones Display
Each zone that did not trip at least once during the Walk Test displays on the keypad
that initiated the test. Any Panic (PN) or Supervisory (SV) 24-hour zone that is faulted
at the end of the Walk Test displays a trouble condition for that zone regardless of the
message programmed for the open or short condition of the zone and a zone trouble is 
sent to the receiver. Press the COMMAND key to display the next failed zone.
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02          0/0
HALLWAY LIGHT
99/99    SUCCESSFUL
WALK TEST
WALK TEST
TRIPS: XXX   
END
TEST END WARNING
SOUTH LOBBY
ZONE: 10 
  -FAIL