Sam Ash Music Corporation AG300 User Manual
Tuning Up Procedure
FCC ID: CCRAG300
AG300 PCB Adjustment & Confirmation Method
No Item
Details
Adjustment Point
Settings/Standards
Notes
1
Initial Setting
Set PCB and channel
Channel setting is depend on
the IR signal from the RX
AR300
the IR signal from the RX
AR300
PCB power switch = ON
2
Power supply input
Supply power at battery
terminal.
terminal.
1.5V
3
Consumption Current
Confirmation
Confirmation
Consumption current at
1.5V.
1.5V.
120mA
There is no signal input
4
Internal Voltage
Confirmation
Confirmation
Ouput voltage of DC-DC
Converter.
Converter.
3.3V
5
Frequency Adjustment
Adjust each channel to the
specified frequency
(639.025MHz –
647.000MHz, 25KHz
Interval).
specified frequency
(639.025MHz –
647.000MHz, 25KHz
Interval).
VC2
Specified frequency
+/-5kHz.
+/-5kHz.
6
RF Output Level
Adjustment
Adjustment
Adjust the output RF level
VR1
+2.5mW - +3.5mW
7
Spurious Level
Confirmation
Confirmation
Check by spectrum
analyzer.
analyzer.
Less than 1uW.
8
AF Amplifier Adjustment
Adjust the audio input level
to ensure deviation and
distortion comply with the
specification
to ensure deviation and
distortion comply with the
specification
VR2
9
Deviation Adjustment
Adjust the deviation less
than 40kHz.
than 40kHz.
VC1, VR3
Less than 40KHz
When input signal rise
to input 1kHz THD4%
to input 1kHz THD4%
10
Distortion Ratio
Confirmation
Confirmation
Adjust by audio output from
receiver.
receiver.
Less than 2%
1kHz DEV= 20kHz and
both of 6.7kHz on the
other hand
both of 6.7kHz on the
other hand
11
Frequency Response
Confirmation
Confirmation
Adjust by audio output from
receiver.
receiver.
+/-3.5dB over 50Hz to 15kHz
Audio input level at
-50dBv
-50dBv