ademco 8DL5800PIRESAP User Manual

Page of 2
     5800PIRRES-AP Wireless Motion Sensor  - Installation Instructions 
 
 
PRELIMINARY DRAFT 8/24/09
 
2 -
  
 
ENROLL THE SENSOR 
Enroll the sensor in the control panel prior to its usage in the 
system. Refer to the control panel instructions for programming 
details. Program the sensor as an “RF” type (supervised 
RF) device.  
To enroll:
 connect the battery and wait for power up to end 
(see LED Indications table). When prompted for the serial 
number, activate the sensor (wave a hand in front of the lens) 
to enroll the sensor. 
Loop 1 
Pulse count 2;  Up to 80 lbs. Animal Immunity  
LED INDICATIONS 
Power Up
Blinks once per second (for < 45 seconds)
Indicator LED
Walk Test
ON for 3 seconds = Loop 1 / Low Sensitivity Alarm 
Flickers rapidly for 3 seconds = walk test period ended
Condition
 
MOUNT THE SENSOR (See page 1)  
Before mounting the transmitter permanently, conduct Go/No 
Go tests (see control panel manual) to verify adequate signal 
strength and reorient or relocate the sensor if necessary. 
For Animal (Pet) Immunity: 
•  Install the sensor where animals cannot come within 6 ft  
(1.8 m) of the sensor by climbing on furniture or other 
objects. 
•  Aim the sensor away from stairways, furniture or other 
objects that can be climbed on by animals.  
•  Do not use optional swivel mount brackets. 
WALK TESTING  
The 10 minute walk test mode begins after power up, and can 
be restarted by removing and replacing the battery.   
As you walk through the detection pattern, the sensor LED will 
light for 3 seconds to indicate each alarm detection.  
Note: In walk test mode all transmissions will be sent as they 
occur. During normal operation, only one transmission 
sequence will occur within a 3-minute period to conserve 
battery life. 
TROUBLESHOOTING 
Problem: The system displays a “low battery” message. 
Solution: Replace the battery within 7 days. 
SPECIFICATIONS 
 
Power: Battery* (included).   
1  x  3 V,  Lithium; 
CR123A / DL123 / DL 123A / 466 
Battery Life, years (typical):     
RF Frequency: 
315 MHz 
Operating Temperature: 
(for indoor use environment)
 
14° to 131° F (-10° to 55° C) 
Relative Humidity, no 
condensation: 
95% max. 
Detectable Walk Rate: 
0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.) 
Temperature Compensation:   Advanced Dual Slope 
 
 
 
 
APPROVALS / LISTINGS 
• FCC  
• IC 
• C-Tick 
• CE 
•  SIA-PIR-01    Passive Infrared detector standard features 
for false alarm immunity. 
• cETLus Listed 
COMPLIANCE NOTES 
•  Product must be tested at least once each year. 
•  Product must be installed within the protected area only. 
 
 
 
 
 
 
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS 
The user shall not make any changes or modifications to the equipment unless authorized by the 
Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's 
authority to operate the equipment. 
 
FCC / IC STATEMENT 
This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is 
subject to the following two conditions:  (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may cause 
undesired operation.  
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. 
Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer 
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les 
interférences causant une réception indésirable.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 2009 Honeywell International Inc.  Honeywell is a registered trademark of Honeywell International Inc.   
All other trademarks are the properties of their respective owners.  All rights reserved.    Assembled in Mexico. 
For the latest U.S. warranty information, please go to:  www.honeywell.com/security/hsc/resources/wa  or 
Please contact your local authorized Honeywell representative for product warranty information. 
 
 
Ê800-13192-Š
P/N 800-13192  Rev A    10/12
 
 
* Battery Caution: Risk of fire, explosion and burns.  Do not recharge, 
disassemble, heat above 212° F (100° C), or incinerate.  Dispose of 
used batteries promptly.  Keep away from children. 
2 Corporate Center Drive, Suite 100
 
P.O. Box 9040, Melville, NY 11747 
www.honeywell.com/security