ENROLL THE SENSOR
Enroll the sensor in the control panel prior to its usage in the
system. Refer to the control panel instructions for programming
details. Program the sensor as an “RF” type (supervised
RF) device.
To enroll: connect the battery and wait for power up to end
(see LED Indications table). When prompted for the serial
number, activate the sensor (wave a hand in front of the lens)
to enroll the sensor.
system. Refer to the control panel instructions for programming
details. Program the sensor as an “RF” type (supervised
RF) device.
To enroll: connect the battery and wait for power up to end
(see LED Indications table). When prompted for the serial
number, activate the sensor (wave a hand in front of the lens)
to enroll the sensor.
Loop 1
Pulse count 2; Up to 80 lbs. Animal Immunity
LED INDICATIONS
Power Up
Blinks once per second (for < 45 seconds)
Indicator LED
Walk Test
ON for 3 seconds = Loop 1 / Low Sensitivity Alarm
Flickers rapidly for 3 seconds = walk test period ended
Flickers rapidly for 3 seconds = walk test period ended
Condition
MOUNT THE SENSOR (See page 1)
Before mounting the transmitter permanently, conduct Go/No
Go tests (see control panel manual) to verify adequate signal
strength and reorient or relocate the sensor if necessary.
For Animal (Pet) Immunity:
• Install the sensor where animals cannot come within 6 ft
Go tests (see control panel manual) to verify adequate signal
strength and reorient or relocate the sensor if necessary.
For Animal (Pet) Immunity:
• Install the sensor where animals cannot come within 6 ft
(1.8 m) of the sensor by climbing on furniture or other
objects.
objects.
• Aim the sensor away from stairways, furniture or other
objects that can be climbed on by animals.
• Do not use optional swivel mount brackets.
WALK TESTING
The 10 minute walk test mode begins after power up, and can
be restarted by removing and replacing the battery.
As you walk through the detection pattern, the sensor LED will
light for 3 seconds to indicate each alarm detection.
Note: In walk test mode all transmissions will be sent as they
occur. During normal operation, only one transmission
sequence will occur within a 3-minute period to conserve
battery life.
be restarted by removing and replacing the battery.
As you walk through the detection pattern, the sensor LED will
light for 3 seconds to indicate each alarm detection.
Note: In walk test mode all transmissions will be sent as they
occur. During normal operation, only one transmission
sequence will occur within a 3-minute period to conserve
battery life.
TROUBLESHOOTING
Problem: The system displays a “low battery” message.
Solution: Replace the battery within 7 days.
Solution: Replace the battery within 7 days.
SPECIFICATIONS
Power: Battery* (included).
1 x 3 V, Lithium;
CR123A / DL123 / DL 123A / 466
CR123A / DL123 / DL 123A / 466
Battery Life, years (typical): 5
RF Frequency:
315 MHz
Operating Temperature:
(for indoor use environment)
(for indoor use environment)
14° to 131° F (-10° to 55° C)
Relative Humidity, no
condensation:
condensation:
95% max.
Detectable Walk Rate:
0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.)
Temperature Compensation: Advanced Dual Slope
APPROVALS / LISTINGS
• FCC
• IC
• C-Tick
• CE
• SIA-PIR-01 Passive Infrared detector standard features
• IC
• C-Tick
• CE
• SIA-PIR-01 Passive Infrared detector standard features
for false alarm immunity.
• cETLus Listed
COMPLIANCE NOTES
• Product must be tested at least once each year.
• Product must be installed within the protected area only.
COMPLIANCE NOTES
• Product must be tested at least once each year.
• Product must be installed within the protected area only.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the
Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
The user shall not make any changes or modifications to the equipment unless authorized by the
Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules and RSS-210 of the IC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada.
Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.
Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.
2009 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
Please contact your local authorized Honeywell representative for product warranty information.
Ê800-13192-Š
P/N 800-13192 Rev A 10/12
* Battery Caution: Risk of fire, explosion and burns. Do not recharge,
disassemble, heat above 212° F (100° C), or incinerate. Dispose of
used batteries promptly. Keep away from children.
used batteries promptly. Keep away from children.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security