ademco 8DL5800SS2 User Manual

Page of 2
 
GENERAL INFORMATION 
The 5800SS1 is a wireless shock sensor 
intended for use in systems that support 5800 
series devices. Each transmitter has its own 
unique serial number, assigned during 
manufacture, which must be “enrolled” in the 
control panel before the device can be used 
with the system.  Refer to the control panel's 
Installation and Setup Guide for programming 
details. 
One 5800SS1 is required for each pane of 
glass protected. (Do not use more than one 
sensor per pane.) 
Types of Glass Protection 
• Tempered 
• Ordinary 
Plate 
• Laminated 
Type 
• Wired 
• Coated
*
 
• Sealed 
Insulated 
*
 Not for use in UL installations. 
Note:  It is not necessary to remove the case 
cover during installation. 
ENROLLING THE 5800SS1  
You must enroll the 5800SS1  serial number 
in the control panel during zone 
programming. The control panel's Installation 
and Setup Guide provides detailed 
programming procedures.  Before 
programming, perform the following: 
1.  To cause the transmitter to transmit, 
remove the “PULL TO CONNECT 
BATTERY” tab (see Figure 1). (For 
additional transmissions, lightly tap on 
the base of the sensor with a 
screwdriver.) 
PULLTOCONNECTBATTERY
K5867
5800SS1-001-V0
PULL
TAB
SENSOR
 
Figure 1 
2. 
When programming the shock 
sensor, note the following: 
• 
Input Type = 3 (Supervised RF) 
• 
Loop Number = 1
 
3. 
When prompted for the serial number, 
you can transmit by lightly tapping on 
the base of the sensor with a 
screwdriver or by manually entering 
the serial and loop number. 
MOUNTING  
1.  Determine the optimum mounting 
location. For best sensitivity, the 
sensor should be mounted one-inch 
from the corner edge of the window 
frame (see Figure 2). 
1in.
1in.
10 FT. RADIUS
MAXIMUM
COVERAGE
STRIKE AT
FURTHEST
OPPOSITE
CORNER WITH
SCREWDRIVER
HANDLE
MOUNT 1 INCH FROM CORNER
OF WINDOW FRAME.
5800SS1-003-V0
 
Figure 2 
2.  Before the transmitter is permanently 
mounted, conduct Go/No Go tests (see 
control’s instructions) to verify adequate 
signal strength from the mounting 
location. 
3.  Always verify range by holding the 
sensor in the approximate mounting 
location and tapping at the base. The 
panel (in test mode) should respond to 
the transmissions. If not, find a more 
suitable mounting location. 
4. 
Clean the glass, where the sensor will be 
mounted, with a mixture of water and 
isopropyl alcohol. 
5. 
Once the glass has dried, remove the 
tape backing paper and firmly press the 
sensor in the desired mounting location. 
6. 
Verify operation by striking the furthest 
opposite corner of the glass with the 
handle of a large screwdriver. Always 
check the alarm panel keypad to verify 
that the zone has tripped. 
7. 
Apply optional “WARNING” label to the  
 
outside glass surface opposite the tape 
side of the 5800SS1. 
5800SS1 
5800SS1 
5800SS1 
5800SS1 
    
Wireless Shock Sensor 
Wireless Shock Sensor 
Wireless Shock Sensor 
Wireless Shock Sensor ----    Installation Guide
 
 
FCC / IC STATEMENTS ARE IN THE MIDDLE OF PAGE 2