ademco 8DL5828V1 User Manual

Page of 4
 
- 3 - 
Function Key 
Function 
“Off” 
Arms “AWAY” 
Arms “STAY” 
(For future use) 
MEMO/MESSAGE CENTER 
The MESSAGE CENTER table that follows explains what 
can be done using the message center of the 5828V, and the 
keys to press to enable each function. 
 
NOTE: Allow any status annunciation to complete before 
starting to record a message.   
 
MESSAGE CENTER (LYNX)
 
TO: 
PRESS: 
Record a message: 
# + 1 
Stop recording before end of 20 seconds: 
Playback a message: 
# + 3 
Adjust message playback volume: 
# + 2 + 3↑ or 6↓ 
Mute keypad status announcements: 
# + 2 + 1 
Restore keypad status announcements: 
# + 2 + 3↑ or 6↓ 
MESSAGE CENTER (VISTA)
 
TO: 
PRESS: 
Record a message: 
# + 0 + 1 
Stop recording before end of 20 seconds: 
Playback a message: 
# + 0 + 3 
Adjust message playback volume: 
# + 0 + 2 + 3↑ or 6↓ 
Mute keypad status announcements: 
# + 0 + 2 + 1 
Restore keypad status announcements: 
# + 0 + 2 + 3↑ or 6↓ 
New message indication: When the keypad is activated in 
battery-powered mode and a new message is waiting, the red 
message LED will blink until the keypad turns off or the 
message is played back. 
When powered by AC, if a new message is waiting, the red 
message LED will blink continuously until the stored 
message has been played back. 
NOTE: If using a LYNX control, and the word “MESSAGE” 
is announced at the 5828V keypad, it means that there is a 
message waiting at the control panel, which can only be 
retrieved using the LYNX keypad. 
 
To delete a message: Recording a new message will 
overwrite the old one. 
 
Muting system status announcements has NO affect on 
the message recording or playback capability. 
If volume is adjusted (3↑ or 6↓) when a message is played 
back, and the user still wants system status announcements 
to be muted, the user must again mute system status 
announcements (# + 2 + 1 for LYNX or # + 0 + 2 + 1 for 
VISTA). 
POWER CONNECTIONS 
In a typical configuration, the 5828 and 5828V keypads are 
powered by 3-AA batteries. 
  
The 5828 and 5828V keypads can also be powered from an 
optional Power Pack/Desktop Mounting Kit. See detailed 
specifications for the Kit on the next page. 
 
It is recommended that three AA batteries be installed as a 
backup power source when using the Power Pack/Desktop 
Mounting Kit. 
 
SUPERVISION 
A 5828/5828V keypad low battery condition will be 
displayed as “BAT” on Zone “00” until the battery drops 
below a minimum level and the display goes blank. 
The 5828/5828V does not display three-digit conditions, such 
as a keypad or receiver supervision failure.  It will only 
display the last two digits of the supervision zone number.  
Therefore, it is recommended for VISTA-10P/15P/20P and 
variants that you set program field *199 (ECP Fail Display) 
as a “1” (two-digit display).  This will cause the keypad to 
display Zone 91 as a supervision failure of any device on the 
keypad (ECP) bus. 
 
NOTE: 
When  programming  zone  descriptors  in  the  panel,  you  must  select  from  words  supported  by  both  the  5828V 
(shown  in  Table  1  below)  and  words  supported  by  the  control  panel.  If  you  use  any  other  words,  the  5828V  will  not 
annunciate  them.  Refer  to  the  control  panel’s  Installation  and  Setup  Guide  for  specific  instructions  on  programming 
zone descriptors.
 
TABLE 1. ZONE DESCRIPTORS
 
ALARM 
DOOR 
GUN 
MOTION 
SEVEN 
THREE 
ATTIC 
EIGHT 
INSIDE 
NINE 
SHED 
TWO 
BABY 
EMERGENCY 
INSTANT 
OFFICE 
SHOP 
UPSTAIRS 
BACK 
EXIT 
KITCHEN 
ONE 
SIDE 
UTILITY 
BASEMENT 
FIRE 
LAUNDRY 
OPEN* 
SIX 
WINDOW 
BATHROOM 
FIRST 
LIBRARY 
PANIC* 
SLIDING 
YARD 
BEDROOM 
FIVE 
LIVING 
PATIO 
SMOKE 
ZERO 
CHECK 
FLOOR 
MAIN 
POOL 
STORAGE 
ZONE 
DEN 
FOUR 
MASTER 
MOTION 
SEVEN 
 
DETECTOR 
FRONT 
MEDICAL 
ROOM 
SYSTEM 
 
DINING  
GARAGE  
MESSAGE** 
SECOND 
THIRD 
 
  *  These Descriptors are available with VISTA series control panels ONLY. 
  **  This Descriptor is available with Lynx series control panels ONLY. 
 
 
 
1.  If installing a Lynx series system, please note that compound zone descriptors supported by the Lynx such as “living 
room” are not supported on the 5828V, and should be programmed as two single words, “living” and “room.”  Also 
note that the Lynx Voice Prompt Programming mode uses these compound words when applicable.  These words 
should be reprogrammed as two single words in order to be announced by the 5828V. 
2.  When using a VISTA-40 or VISTA-50P control panel, you must program zone descriptors in order for the panel to 
announce the zone status correctly.